Permit Case Summary

Case Number: Search Help

Case Number:SEP2015-00015 Case Status:Finaled Date Received:2/10/2015
Description:tank & transport line only to SEP12-104 filed here Date Issued:4/17/2015
Applicant: POPE RESOURCES Expiration Date:4/17/2018 12:00:00 AM
Site Address:1501 WAHL LAKE RD Case Finaled:2/4/2016
Parcel No:801361001 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 2/4/2016
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed: 9/11/2015
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed: 7/17/2015
Disposition: DONE
Description: Issue permit (Fm) "A"
Date Completed: 4/17/2015
Disposition: DONE
Description: Pending letter; add inf (Fm)
Date Completed: 4/17/2015
Disposition: DONE
Description: Monitoring Agreemt Sent (Fm)
Date Completed: 9/10/2015
Disposition: DONE
Description: Pressure test required
Date Completed: 9/11/2015
Disposition: DONE
Description: Invoice for DCD Sent
Date Completed: 3/10/2015
Disposition: DONE
Description: Septic Permit Application (Fm)
Date Completed: 2/10/2015
Disposition: DONE
Description: Override - Parcel Holds
Date Completed: 2/17/2015
Disposition:
Description: Asbuilt drawing submitted
Date Completed: 9/10/2015
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 3/25/2015
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 3/9/2015
Disposition: DONE
Description: Case Entered "P"
Date Completed: 2/17/2015
Disposition:
Description: Stormwater Review-U
Date Completed: 3/25/2015
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pressure test observation
Wording Health Dept. required to observe pressure test with system designer when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be sleeved/cased or equivalent.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength wastewater only. Disposal of any other waste strength is considered a violation of this permit.

Title: design flow/water usage monitorin
Wording Exceeding the permitted design flow of 490 gal/day shall constitute a violation of this permit. Water usage monitoring shall be conducted monthly via the dose counter in the control panel. These monitoring results shall be submitted to the Jefferson County Health Dept. as requested. NO FUTURE APPROVALS FROM THIS OFFICE SHALL BE APPROVED WITHOUT THIS DATA.

Title: PUMP CHAMBER
Wording Pump chamber shall be water tight and a minimum capacity of 1000gal. It shall be equipped with a control panel outside within line of sight of the pump chamber. The panel shall have an audio and visual alarm, a cycle counter and a riser to grade. It shall be UL listed and meet L&I requirements.

Title: SCREEN REQUIRED
Wording A screen shall be provided at the outlet of the septic tank. A screen or shroud is required around the pump

Title: O & M Manual required
Wording Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system.

Title: System capacity/uses
Wording Approval of this permit does not assure the existing septic system has capacity for all uses allowed by current code.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS.

Title: Installation Inspection
Wording Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start.

Title: No Building Permit Guaranteed
Wording Approval/issuance of a sewage disposal permit or installation of a septic system does not guarantee the approval of other development or a building permit on this site. Future buildings that require connection to an on-site sewage system (OSS) shall only be approved if the OSS meets the current standards and codes in effect at the time of the building application.

Title: Code Compliance
Wording All construction and development activities must comply with all permit conditions, Washington State and Jefferson County Codes and Recommended Standards and Guidance documents in effect when the permit is issued.

Title: EXISTING WATER LINE
Wording Tthe existing water line must be located and a 10' separation maintained from any septic component

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.