Permit Case Summary

Case Number: Search Help

Case Number:SEP2000-00122 Case Status:Finaled Date Received:5/26/2000
Description: Date Issued:6/23/2000
Applicant: OLYMPIC RESOURCE MANAGEMENT Expiration Date:6/23/2003 12:00:00 AM
Site Address: ROCKTOGO RD Case Finaled:6/5/2002
Parcel No:821312001 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 6/5/2002
Disposition: DONE
Description: OSS Inspection-1 Year
Date Completed: 7/16/2002
Disposition: DONE
Description: Issue permit (F)
Date Completed: 6/23/2000
Disposition: DONE
Description: Case Entered
Date Completed: 5/26/2000
Disposition:
Description: Stormwater Review
Date Completed: 6/16/2000
Disposition: DONE
Description: Review Case
Date Completed: 6/23/2000
Disposition: DONE
Description: Critical Area Review
Date Completed: 6/16/2000
Disposition: DONE
Description: Pressure test required
Date Completed: 6/28/2000
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 5/26/2000
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test, 48 hour notice to be given.

Title: asbuilt required
Wording An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: SAND LINED TRENCH/BED
Wording TRENCH TO BE EXCAVATED TO 48" DEPTH AND THEN BACKFILLED WITH ASTM 33 TYPE SAND TO 24" AND UP SIDE WALLS AS PER DESIGN.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength waste water only. Disposal of any other waste streams is considered a violation of this permit.

Title: design flow/water usage monitorin
Wording Exceeding the permitted design flow of 804 gal/day shall constitute a violation of this permit. Water usage monitoring shall be conducted when requested. These monitoring results shall be submitted to the Jefferson County Health Dept.

Title: risers
Wording Risers are required to grade with secured lids over the inlet and outlet of the septic tank. Minimum 24" riser over inlet.