Permit Case Summary

Case Number: Search Help

Case Number:SEP2000-00078 Case Status:Finaled Date Received:4/25/2000
Description:SEP81-36 Filed here Drainfield on easement "D" on parcel 821333004 Date Issued:7/11/2000
Applicant:JANET STIMACH Expiration Date:7/11/2003 12:00:00 AM
Site Address:351 MARGARET ST Case Finaled:6/7/2001
Parcel No:821333005 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: OSS Inspection-3 Year
Date Completed: 9/16/2003
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 6/7/2001
Disposition: DONE
Description: Pressure test required
Date Completed: 8/7/2000
Disposition: DONE
Description: Issue permit (F)
Date Completed: 7/11/2000
Disposition: DONE
Description: Pending letter; add inf (F)
Date Completed: 7/11/2000
Disposition: DONE
Description: Case Entered
Date Completed: 4/26/2000
Disposition:
Description: Stormwater Review
Date Completed: 6/14/2000
Disposition: DONE
Description: Review Case
Date Completed: 7/11/2000
Disposition: DONE
Description: Critical Area Review
Date Completed: 6/14/2000
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 4/26/2000
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording THIS SITE RECEIVED A WAIVER FROM SETBACK REQUIREMENTS TO A WELL AND SURFACE WATER TO AN EFFLUENT TRANSPORT LINE. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test, 48 hour notice to be given.

Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines except as specifically allowed under the approved waiver.

Title: other setbacks req.
Wording 100 ft. setback from surface water to be maintained from primary and reserve drainfield areas.

Title: trench depth
Wording MAXIMUM TRENCH DEPTH 24 INCHES

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required.

Title: easement
Wording Recorded easement required for primary and/or reserve drainfields and other portions of onsite sewage system. Easement to be recorded with the Jefferson County Auditors office prior to final approval of the system.

Title: Tank Abandonment
Wording Existing tank shall be properly abandoned. It shall be pumped and filled with clean fill. Documentation to be provided to Health Dept. prior to final.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around tanks.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area, transport line and tanks.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: critical area waiver cond.
Wording Compliance with the conditions of the signed Critical Area Waiver is required.

Title: state onsite regs waiver
Wording This site has been granted a waiver from the state onsite sewage regulation 246-272-09501, 50' setback from wells to effluent transport line and 10' setback from surface water to effluent transport line. Compliance with conditions of the waiver is required: Setback to well to be no less than 25' and to be maximized to the greatest extent possible, effluent transport line to be double cased in C900 or ductile iron continuously where within 50' of well and/or 10' of surface water, effluent line to be no less than 5' to surface water, system to be monitored by an approved entity at a minimum of every 3 years or as required by Jefferson County Code 8.15.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength waste water only. Disposal of any other waste streams is considered a violation of this permit.

Title: risers
Wording Risers are required to grade with secured lids over the inlet and outlet of the septic tank. Minimum 24" riser over inlet.