Permit Case Summary

Case Number: Search Help

Case Number:SEP1998-00149 Case Status:Finaled Date Received:7/9/1998
Description: Date Issued:9/3/1998
Applicant:MARTY PETERSON Expiration Date:9/3/1999 12:00:00 AM
Site Address:10712 RHODY DR Case Finaled:6/11/1999
Parcel No:942903506 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: File Review by Specialist
Date Completed: 3/25/2021
Disposition:
Description: OSS Inspection-3 Year
Date Completed: 12/24/2003
Disposition: DONE
Description: OSS Inspection-1 Year
Date Completed: 12/13/2002
Disposition: DONE
Description: OSS Inspection-1 Year
Date Completed: 8/12/2002
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 6/11/1999
Disposition:
Description: Easement required
Date Completed: 6/2/1999
Disposition:
Description: Issue permit (F)
Date Completed: 9/3/1998
Disposition: ISS
Description: Case Entered
Date Completed: 7/9/1998
Disposition:
Description: Stormwater Review
Date Completed: 7/15/1998
Disposition:
Description: Review Case
Date Completed: 9/3/1998
Disposition: ISS
Description: Critical Area Review
Date Completed: 7/16/1998
Disposition: OKAY
Description: PUD contract required
Date Completed: 6/8/1999
Disposition:
Description: AsBuilt from engineer req
Date Completed: 6/4/1999
Disposition:
Description: Pressure test required
Date Completed: 4/13/1999
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 7/10/1998
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test, 48 hour notice to be given.

Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: trench depth
Wording MAXIMUM TRENCH DEPTH 12 INCHES

Title: easement
Wording Recorded easement required for primary and/or reserve drainfields prior to final. Easement to be recorded with the Jefferson County Auditors office.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around drainfield.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: reduced size df
Wording Performance monitoring schedule for treatment systems followed by reduced sized drainfield/infiltrative area shall be :1) Two times per year (once every six months) during the first and second year following installation. 2) One time per year beginning with the third year following installation. 3) In response to complaints or problems. Observation ports to the bottom of the trench are to be installed in at least two places on each drainfield line: One within 10 feet of the beginning of each line and one within 10 feet of the end of each line.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength waste water only. Disposal of any other waste streams is considered a violation of this permit.

Title: BOD-WASTE STRENGTH MONITORING
Wording If waste exceeding domestic strength waste parameters is disposed of into this system then waste strength (BOD, TSS, Grease and oils) is to be monitored quarterly for the first year of operation and annually thereafter. Responsibility is that of the owner. Results are to be submitted to the Jefferson County Health Dept.

Title: design flow/water usage monitorin
Wording Exceeding the permitted design flow of 480 gal/day shall constitute a violation of this permit. Water usage monitoring shall be conducted if/when requested by the health jurisdiction. The monitoring results shall be submitted to the Jefferson County Health Dept.