Permit Case Summary

Case Number: Search Help

Case Number:SEP1998-00126 Case Status:Finaled Date Received:6/3/1998
Description:SEP78-44 and SEP80-81 now filed here Date Issued:7/14/1998
Applicant: WA ST FISH & WILDLIFE Expiration Date:7/14/1999 12:00:00 AM
Site Address:1000 POINT WHITNEY RD Case Finaled:10/16/2001
Parcel No:601071001 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: OSS Inspection-2 Year
Date Completed: 8/15/2006
Disposition: DONE
Description: OSS Inspection-Custom Schedule
Date Completed: 8/10/2004
Disposition: DONE
Description: OSS Inspection-1 Year
Date Completed: 8/13/2002
Disposition: 1YR
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 10/16/2001
Disposition: DONE
Description: Issue permit (F)
Date Completed: 7/14/1998
Disposition: ISSU
Description: PUD contract required
Date Completed: 10/16/2001
Disposition: DONE
Description: AsBuilt from engineer req
Date Completed: 6/1/1999
Disposition:
Description: Pressure test required
Date Completed: 3/23/1999
Disposition: DONE
Description: Case Entered
Date Completed: 6/3/1998
Disposition:
Description: Stormwater Review
Date Completed: 6/15/1998
Disposition:
Description: Review Case
Date Completed: 7/14/1998
Disposition: ISSU
Description: Critical Area Review
Date Completed: 6/15/1998
Disposition:
Description: Septic Permit Application (F)
Date Completed: 6/5/1998
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test, 48 hour notice to be given.

Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: other setbacks req.
Wording 10 ft. setback from any water line at the facility must be maintained from all septic system components.

Title: trench depth
Wording MAXIMUM TRENCH DEPTH 6-12 INCHES

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required.

Title: low use water fixures
Wording Low use water fixtures are required per the approved design (see construction note 21 on page 5of5. 1.6 gal. flush toilets and sink faucets that self close.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers may be required around drainfield.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter
Wording Dose counters and timers are required in the control panel for drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tanks and pump chambers.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength waste water only. Disposal of any other waste streams is considered a violation of this permit.

Title: risers
Wording Risers are required to grade with secured lids over the inlet and outlet of all septic tanks. Minimum 24" riser over inlet.

Title: CUSTOM CONDITION
Wording Existing water line is to be abandoned in place and capped at both ends. The new water line must be a minimum of 10 feet from any septic system component.

Title: CUSTOM CONDITION
Wording If during installation any portion of the abandoned water line is dammaged the dammaged section must be cut out and capped at both ends.

Title: CUSTOM CONDITION
Wording A site visit by this office to confirm the existing drainfield and four (4) tanks were abandoned is required prior to receiving a final on this permit. Also required is a copy of the pump receipts for the four tanks.

Title: CUSTOM CONDITION
Wording This office is to be notified two days before to the pre construction meeting.