Permit Case Summary

Case Number: Search Help

Case Number:SEP1997-00245 Case Status:Finaled Date Received:9/19/1997
Description: Date Issued:11/3/1997
Applicant: POPE RESOURCES Expiration Date:11/3/1998 12:00:00 AM
Site Address:6363 THORNDYKE RD Case Finaled:4/6/1998
Parcel No:701251001 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 4/6/1998
Disposition:
Description: Issue permit (F)
Date Completed: 11/3/1997
Disposition: ISS
Description: Pending letter; add inf (F)
Date Completed: 11/3/1997
Disposition: P
Description: Septic Permit Application (F)
Date Completed: 10/2/1997
Disposition:
Description: Case Entered
Date Completed: 9/19/1997
Disposition:
Description: Stormwater Review
Date Completed: 10/29/1997
Disposition: OKAY
Description: Review Case
Date Completed: 11/3/1997
Disposition: ISS
Description: Critical Area Review
Date Completed: 10/29/1997
Disposition: OKAY
Description: Septic Permit Application (F)
Date Completed: 9/24/1997
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: well setback requirement
Wording 100 ft. setback to all wells to be maintained from primary and reserve drainfields. 50 ft setback required from tanks to individual wells.

Title: other setbacks req.
Wording 50 ft. setback from tanks to surface waters to be maintained.

Title: easement
Wording Recorded easement required for primary and/or reserve drainfields prior to final if drainfield is located on a separate parcel from residence. Easement to be recorded with the Jefferson County Auditors office.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around drainfield.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: divert drainage
Wording Divert all sources of drainage away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: critical area waiver cond.
Wording Compliance with the conditions of the signed Critical Area Waiver is required.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength waste water only. Disposal of any other waste streams is considered a violation of this permit.