Permit Case Summary

Case Number: Search Help

Case Number:SEP2021-00221 Case Status:Finaled Date Received:12/6/2021
Description:info from failed SEP1979-00165 filed here Date Issued:12/20/2021
Applicant:FELICIA MACHUCA Expiration Date:3/20/2022 12:00:00 AM
Site Address:66 W FITCHBURG AVE Case Finaled:1/28/2022
Parcel No:952800804 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 1/28/2022
Disposition: DONE
Description: Misc. Conversation or email
Date Completed: 1/13/2022
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed:
Disposition:
Description: Issue permit (Fm) "A"
Date Completed: 12/20/2021
Disposition: DONE
Description: Septic Permit Application (Fm)
Date Completed: 12/7/2021
Disposition: DONE
Description: Monitoring Agreemt Sent (Fm)
Date Completed: 12/14/2021
Disposition: DONE
Description: Document Recorded
Date Completed: 12/7/2021
Disposition: DONE
Description: Miscellaneous Action
Date Completed: 12/7/2021
Disposition: DONE
Description: Update SOM Repair Recd
Date Completed: 12/6/2021
Disposition: DONE
Description: Asbuilt drawing submitted
Date Completed: 1/28/2022
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 12/17/2021
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 12/7/2021
Disposition: DONE
Description: Stormwater Review-U
Date Completed: 12/20/2021
Disposition: DONE
Description: Case Entered "P"
Date Completed: 12/7/2021
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: ONGOING MONITORING
Wording H - AS PER WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 ALL ONSITE SEWAGE SYSTEMS REQUIRE THAT A RESTRICTIVE COVENANT REGARDING THE MONITORING OF THE ONSITE SEPTIC SYSTEM BE RECORDED TO THE PROPERTY TITLE. THE PROPERTY OWNER SHALL ASSURE THAT MONITORING IS PROVIDED BY AN APPROVED ENTITY AT THE FREQUENCY DEFINED PER STATE WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED. A COPY OF THE RECORDED OPERATIONS AND MONITORING AGREEMENT IS REQUIRED PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL PERMIT

Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: trench depth
Wording Trench shall be installed 18" - 25" - 6" into native soils.

Title: Tank Abandonment
Wording H - Existing tank shall be properly abandoned. It shall be pumped and filled with clean fill. Documentation to be provided to Health Dept. prior to final.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: minimum land RESTRICTIVE COV
Wording H - This permit is granted based on the recorded RESTRICTIVE COVENANT combining lots 7, 8, 9 of block 8, Garfields Addition, to meet the minimum land area required under WAC 246-272A Onsite Sewage Code. COVENANT recorded 12/10/21, AFN 650237.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength wastewater only. Disposal of any other waste strength is considered a violation of this permit.

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet.

Title: conventional-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the Designer is required prior to final approval.

Title: riser on d-box
Wording Distribution boxes shall be fitted with a riser to grade, constructed of durable materials and a secured lid, adequately sized to allow visible inspection of the liquid level in the box.

Title: System Capacity-no ADU
Wording This system as designed and approved is sized for only one single family residence. It is not sized for an Accessory Dwelling Unit (ADU). The minimum daily design flow per residence is 240 GPD.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: VIOLATION-limited permit life
Wording This permit was issued to correct a violation of WAC 246-272A. The permit must be completed within 90 days of the date of issuance.

Title: O & M Manual required
Wording Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS.

Title: Installation Inspection
Wording Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start.

Title: No Building Permit Guaranteed
Wording Approval/issuance of a sewage disposal permit or installation of a septic system does not guarantee the approval of other development or a building permit on this site. Future buildings that require connection to an on-site sewage system (OSS) shall only be approved if the OSS meets the current standards and codes in effect at the time of the building application.

Title: Unplumbed Building
Wording The existing un-plumbed 'wood shed' shown on the plot plan is not proposed to be connected to the septic system, nor was there any septic system capacity assigned to it. It is not approved as a bedroom or dwelling unit. As a result, future building permits on the property may require some amount of septic system capacity be assigned to the existing structure or require additional building permitting to officially recognize the structure as a non-habitable space.

Title: Code Compliance
Wording All construction and development activities must comply with all permit conditions, Washington State and Jefferson County Codes and Recommended Standards and Guidance documents in effect when the permit is issued.


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: F-Confirmed ESAs
Wording The Geographic Information Systems mapping review identified the following Critical Areas on the subject property: Critical Aquifer Recharge Area.