Case Number:SEP2017-00199 Case Status:Finaled Date Received:10/3/2017
Description:SEP10-00153 filed here. drainfield located via easement on 901024057 Date Issued:3/16/2018
Applicant:CHARLES E RUSSELL Expiration Date:6/16/2018 12:00:00 AM
Site Address:21 CHIMACUM RD Case Finaled:7/19/2018
Parcel No:901024020 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: Miscellaneous Action
Date Completed: 6/18/2019
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 7/13/2018
Disposition: DONE
Description: Miscellaneous Action
Date Completed: 7/13/2018
Disposition:
Description: INSTALLATION START NOTICE
Date Completed: 6/5/2018
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed: 4/18/2018
Disposition: DONE
Description: Mon Agreement ATU Attach (Fm)
Date Completed: 4/2/2018
Disposition: DONE
Description: Monitoring Agreemt Sent (Fm)
Date Completed: 4/2/2018
Disposition: DONE
Description: Issue permit (Fm) "A"
Date Completed: 3/16/2018
Disposition: DONE
Description: Updated/Add'l Info Recv'd
Date Completed: 2/26/2018
Disposition:
Description: REDESIGN SUBMITTED (Fm) "P"
Date Completed: 3/16/2018
Disposition: DONE
Description: Pending letter; add inf (Fm)
Date Completed: 3/16/2018
Disposition: DONE
Description: Septic Permit Application (Fm)
Date Completed: 10/4/2017
Disposition: DONE
Description: Asbuilt drawing submitted
Date Completed: 4/30/2018
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 10/19/2017
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 3/16/2018
Disposition: DONE
Description: Stormwater Review-U
Date Completed: 3/16/2018
Disposition: DONE
Description: Case Entered "P"
Date Completed: 10/4/2017
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: ONGOING MONITORING
Wording H - AS PER WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 ALL ONSITE SEWAGE SYSTEMS REQUIRE THAT A RESTRICTIVE COVENANT REGARDING THE MONITORING OF THE ONSITE SEPTIC SYSTEM BE RECORDED TO THE PROPERTY TITLE. THE PROPERTY OWNER SHALL ASSURE THAT MONITORING IS PROVIDED BY AN APPROVED ENTITY AT THE FREQUENCY DEFINED PER STATE WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED. A COPY OF THE RECORDED OPERATIONS AND MONITORING AGREEMENT IS REQUIRED PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL PERMIT

Title: pressure test observation
Wording Health Dept. required to observe pressure test with system designer when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required and must comply with code at the time of application for use. WATER TABLE AND VERY FINE SILT LOAM, COMPACT SOILS OBSERVED.

Title: easement
Wording H - Recorded easement required for primary and/or reserve drainfields and to meet minimum land area requirements. Easement recorded 1/3/18 under AFN 613377 with the Jefferson County Auditors office.

Title: Tank Abandonment
Wording H - Existing tank shall be properly abandoned. It shall be pumped and filled with clean fill. Documentation to be provided to Health Dept. prior to final.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter & ETM
Wording Dose counter and elapsed time meter are required in the control panel for all system components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be sleeved/cased or equivalent.

Title: water tight tank
Wording Septic tank and pump chamber to be water tight. Extra protection (i.e. Bentonite) to be used around inlet, outlet, and risers.

Title: SAND LINED TRENCH/BED
Wording TRENCH TO BE EXCAVATED TO 36" - 42" DEPTH AND THEN BACKFILLED WITH COARSE SPEC TYPE SAND AND UP SIDE WALLS AS PER DESIGN.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: food serv annual monitoring
Wording WAC 246-272A REQUIRES ANNUAL MONITORING OF THE ONSITE SEWAGE SYSTEM WHEN IT IS SERVING A FOOD SERVICE ESTABLISHMENT.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength wastewater only. Disposal of any other waste strength is considered a violation of this permit. Proposal for additional food service activities including hours of operation, items served shall require review and additional information and may require additional hydraulic capacity, additional treatment such as a grease trap and/or other treatment device to address high strength waste prior to approval.

Title: BOD-WASTE STRENGTH MONITORING
Wording Waste Strength (BOD, TSS, Grease and oils) is to be monitored quarterly for the first year of operation and annually thereafter. Responsibility is that of the owner. Results are to be submitted to the Jefferson County Health Dept.

Title: design flow/water usage monitorin
Wording Exceeding the permitted design flow of 720 gal/day peak flow shall constitute a violation of this permit. Water use/flows shall be submitted to Jefferson County Public Health upon request. Average water use should be in the range of 475-540 gal/day.

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet. 24" Access risers shall be provided on the pump chamber and treatment unit for service and monitoring.

Title: ATU maintenance
Wording A maintenance and management contract is required with the manufacturers authorized representative. Maintenance of the system shall be completed by a manufacturers authorized representative at the frequency required by the manufacturer.

Title: ATU RECORDING/COMPLIANCE
Wording H - The signed Notice for Maintenance and Monitoring of an Onsite Sewage System shall be recorded to the property title prior to final approval. Non-compliance with the contract or maintenance requirements is a violation of this permit.

Title: protective barriers
Wording H - Permanent barriers are required along/around septic tanks, pump chamber and treatment unit areas to protect from parking, driving, and other land disturbing activities prior to final. Barriers shall be required to protect the primary and reserve drainfield areas when/if the property is developed.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: Setback - Drains
Wording A 30' setback shall be maintained from the disposal component and reserve area to any downslope footing, curtain or interceptor drain or drainage ditch.

Title: VIOLATION-limited permit life
Wording This permit was issued to correct a violation of WAC 246-272A. The permit must be completed within 90 days of the date of issuance.

Title: PUMP CHAMBER
Wording Pump chamber shall be water tight and a minimum capacity of 1,500 gallons. It shall be equipped with a control panel outside within line of sight of the pump chamber. The panel shall have an audio and visual alarm, a cycle counter and a riser to grade. It shall be UL listed and meet L&I requirements. Designer shall provide documentation/statement if intrinsically safe wiring is not installed on this commercial system.

Title: SCREEN REQUIRED
Wording A screened pump vault shall be provided around the pump.

Title: O & M Manual required
Wording Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system.

Title: System capacity/uses
Wording Approval of this permit does not assure the existing septic system has capacity for all uses allowed by current code.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS.

Title: Installation Inspection
Wording Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start.

Title: Certified Installer Required
Wording This system must be constructed by an installer certified by the Jefferson County Public Health Department per Jefferson County Code 8.15.120 (9) and state code WAC246-272A-0250.

Title: No Building Permit Guaranteed
Wording Approval/issuance of a sewage disposal permit or installation of a septic system does not guarantee the approval of other development, permit or a building permit on this site. Future buildings or uses that require connection to an on-site sewage system (OSS) shall only be approved if the OSS meets the current standards and codes in effect at the time of the building application.

Title: Code Compliance
Wording All construction and development activities must comply with all permit conditions, Washington State and Jefferson County Codes and Recommended Standards and Guidance documents in effect when the permit is issued.

Title: Contaminated Material - onsite
Wording H - The material that is removed from the system that has come into contact with waste water must be treated/decontaminated prior to final disposal. The material from the system shall be removed and placed as described in the design to allow for pathogen die-off. The material shall be placed in lifts of no more than 6"-8", each lift covered with lime. It shall be covered and protected from erosion (covered with 6 inches of uncontaminated soil or other approved material covered with straw, etc.).

Title: FUTURE DEVEL.ON DF EASEME-NO HOLD
Wording Any development on the property/lot that contains the drainfield easement shall comply with Nitrogen BMP's if required in the UDC based on less than 1 acre remaining available outside the easement area for 901024020.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.