Permit Case Summary

Case Number: Search Help

Case Number:SEP2017-00181 Case Status:Finaled Date Received:9/7/2017
Description:APPLICATION TO ADD 1 DRAINLINE TO EXISTING SYSTEM SEP15-00033 TO MAKE 480 GPD TO ACCOMODATE BLD17-00493 Date Issued:12/7/2017
Applicant:PATRICK FOWLER Expiration Date:12/7/2020 12:00:00 AM
Site Address:51 MASONIC HALL RD Case Finaled:5/31/2018
Parcel No:994800601 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 5/31/2018
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed: 4/11/2018
Disposition: DONE
Description: Monitoring Agreemt Sent (Fm)
Date Completed: 2/15/2018
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed:
Disposition:
Description: Issue permit (Fm) "A"
Date Completed: 12/7/2017
Disposition: DONE
Description: Miscellaneous Action
Date Completed: 12/5/2017
Disposition: DONE
Description: Pending letter; add inf (Fm)
Date Completed: 12/7/2017
Disposition: DONE
Description: Septic Permit Application (Fm)
Date Completed: 9/8/2017
Disposition: DONE
Description: Pressure test required
Date Completed: 4/11/2018
Disposition: DONE
Description: Asbuilt drawing submitted
Date Completed: 5/31/2018
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 9/28/2017
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 9/27/2017
Disposition: DONE
Description: Stormwater Review-U
Date Completed: 9/27/2017
Disposition: DONE
Description: Case Entered "P"
Date Completed: 9/8/2017
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pressure test observation
Wording Health Dept. required to observe pressure test with system designer when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: other setbacks req.
Wording Drainfield and reserve must maintain a 10' min setback from the proposed foundation per BLD17-00493

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be sleeved/cased or equivalent.

Title: protective barriers
Wording H - Permanent barriers are required along/around primary and reserve drainfield areas to protect from parking, driving, and other land disturbing activities prior to final.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: O & M Manual required
Wording Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS.

Title: Installation Inspection
Wording Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start.

Title: Code Compliance
Wording All construction and development activities must comply with all permit conditions, Washington State and Jefferson County Codes and Recommended Standards and Guidance documents in effect when the permit is issued.

Title: DESCRIPTION OF PLAN
Wording This permit is to expand SEP15-00033 (360 gpd system finaled in 2/17/16) to provide a capacity of 480gpd by adding one 50' lateral to the existing system and modifiing the pump and manifold. This permit is in association with BLD17-00493. See BLD permit application for site plan provided for the new 2 bedroom ADU to be added to the property. This system will serve the primary residence and proposed ADU for a total capacity of 480 gpd.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: F-No ESAs Found
Wording The application was reviewed by Jefferson County staff, via a GIS map review, for the presence of Critical Areas as described in the UDC and has concluded that the property DOES NOT contain Critical Areas. Future proposals will be subject to a new review and conditions may be added if Critical Areas are found on the property.