Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 12/8/2015
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed: 12/3/2015
Disposition: DONE
Description: Attached Document
Date Completed: 11/12/2015
Disposition: DONE
Description: Monitoring Agreemt Sent (Fm)
Date Completed: 11/24/2015
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed: 9/17/2015
Disposition: DONE
Description: Issue permit (Fm) "A"
Date Completed: 4/22/2015
Disposition: DONE
Description: Pressure test required
Date Completed: 12/3/2015
Disposition: DONE
Description: AsBuilt from engineer req
Date Completed: 11/25/2015
Disposition: DONE
Description: REDESIGN SUBMITTED (Fm) "P"
Date Completed: 4/22/2015
Disposition: DONE
Description: Pending letter; add inf (Fm)
Date Completed: 4/22/2015
Disposition: DONE
Description: Additional Info Request-DRD
Date Completed: 2/19/2015
Disposition: DONE
Description: Invoice for DCD Sent
Date Completed: 12/30/2014
Disposition:
Description: DCD Review Time
Date Completed: 12/30/2014
Disposition:
Description: Up Front Review
Date Completed: 12/30/2014
Disposition: DONE
Description: Septic Permit Application (Fm)
Date Completed: 12/22/2014
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 2/6/2015
Disposition: DONE
Description: Stormwater Review-U
Date Completed: 4/22/2015
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 12/30/2014
Disposition: DONE
Description: Case Entered "P"
Date Completed: 12/23/2014
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: ONGOING MONITORING
Wording H - AS PER WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 ALL ONSITE SEWAGE SYSTEMS REQUIRE THAT A RESTRICTIVE COVENANT REGARDING THE MONITORING OF THE ONSITE SEPTIC SYSTEM BE RECORDED TO THE PROPERTY TITLE. THE PROPERTY OWNER SHALL ASSURE THAT MONITORING IS PROVIDED BY AN APPROVED ENTITY AT THE FREQUENCY DEFINED PER STATE WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED. A COPY OF THE RECORDED OPERATIONS AND MONITORING AGREEMENT IS REQUIRED PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL PERMIT

Title: pressure test observation
Wording Health Dept. required to observe pressure test with system designer when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: well setback requirement
Wording Setbacks to all existing wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required and must comply with code at the time of application for use.

Title: Tank Abandonment
Wording H - Existing tank shall be properly abandoned. It shall be pumped and filled with clean fill. Documentation to be provided to Health Dept. prior to final.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be sleeved/cased or equivalent. See detail sheet

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength wastewater only. Disposal of any other waste strength is considered a violation of this permit.

Title: protective barriers
Wording H - Permanent barriers are required along/around primary and reserve drainfield areas to protect from parking, driving, and other land disturbing activities prior to final.

Title: protective barriers
Wording H - Permanent barriers are required around Septic and Pump Tanks to protect from vehicular dammage.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components. No crossing permitted here.

Title: VIOLATION-limited permit life
Wording This permit was issued to correct a violation of WAC 246-272A for septic system components installed w/o a permit. The permit must be completed within 90 days of the date of issuance.

Title: O & M Manual required
Wording Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system.

Title: System capacity/uses
Wording Approval of this permit does not assure the existing septic system has capacity for all uses allowed by current code.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS.

Title: Installation Inspection
Wording Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start.

Title: No Building Permit Guaranteed
Wording Approval/issuance of a sewage disposal permit or installation of a septic system does not guarantee the approval of other development or a building permit on this site. Future buildings that require connection to an on-site sewage system (OSS) shall only be approved if the OSS meets the current standards and codes in effect at the time of the building application.

Title: Code Compliance
Wording All construction and development activities must comply with all permit conditions, Washington State and Jefferson County Codes and Recommended Standards and Guidance documents in effect when the permit is issued.

Title: DRAINAGE / STANDING WATER
Wording Keep the primary and reserve drainfield areas 100' from the low area near the 32" culvert just west of the approved drainfield area. Seasonal standing water this area.

Title: COMMERCIAL ACTIVITIES
Wording This septic system is designed and approved for a single family residence with 7 additional employees. No business or other activities on this property, currently or in the future, are allowed to dispose of waste water into this septic system with out obtaining additional permits from this office.

Title: APPROVAL FOR ___ ONLY
Wording This approval is for a new septic system permit only. Any future permits on this site are subject to review for consistency with applicable codes and ordinances and does not preclude review and conditions which may be placed on future permits.

Title: SITE PLAN CHANGES
Wording The site plan as submitted with the septic system permit application on December 22, 2014 has been reviewed for consistency under the UDC, and has been approved by Jefferson County Department of Community Development. Any modifications, changes, and/or additions to the approved site plan shall be resubmitted for review and approval by Jefferson County Department of Community Development.

Title: AQUIFER RECHARGE AREAS
Wording Aquifer Recharge Areas in Jefferson County are characterized by porous geological formations that allow percolation of the surface water into the soils and the underlying zone of saturation. Aquifers are geologic formations that contain sufficient saturated permeable material to yield significant quantities of water to wells and springs. Aquifers serve as the source of drinking water within most of the rural portions of Jefferson County.

Title: ADJACENT FOREST LANDS DISCLOSURE
Wording Jefferson County has determined that the use of real property for agriculture and forestry operations is a high priority and favored use in the county. The county will not consider to be a nuisance those inconveniences or discomforts arising from such operations, if such operations are consistent with commonly accepted best management practices in compliance with local, state, and federal laws. If your real property includes or is within five hundred (500) feet of real property designated as Rural Residential 1:10 or 1:20, Rural Industrial, Rural Commercial, Agriculture, or Forestry, you may be subject to inconveniences or discomforts arising from such farming and forestry operations, including but not limited to noise, tree removal, odors, flies, fumes, dust, smoke, the operation of farm and forestry machinery during any 24-hour period, the storage and disposal or manure, and the application of permitted fertilizers and permitted pesticides. One or more of these inconveniences may occur as a result of agricultural and forestry operations which are in conformance with existing laws and regulations.

Title: Stormwater BMPs