Permit Case Summary

Case Number: Search Help

Case Number:SEP2014-00102 Case Status:Finaled Date Received:7/30/2014
Description: Date Issued:12/24/2014
Applicant:JEFFREY E FISH Expiration Date:3/24/2015 12:00:00 AM
Site Address:100 CURTISS ST Case Finaled:5/29/2015
Parcel No:989400101 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 5/29/2015
Disposition: DONE
Description: Monitoring Agreemt Sent (Fm)
Date Completed: 4/9/2015
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed:
Disposition:
Description: INSTALLATION START NOTICE
Date Completed: 3/20/2015
Disposition: DONE
Description: Issue permit (Fm) "A"
Date Completed: 12/24/2014
Disposition: DONE
Description: Pending letter; add inf (Fm)
Date Completed: 12/24/2014
Disposition: DONE
Description: Septic Permit Application (Fm)
Date Completed: 7/30/2014
Disposition: DONE
Description: Pressure test required
Date Completed: 4/23/2015
Disposition: DONE
Description: Asbuilt drawing submitted
Date Completed: 5/29/2015
Disposition:
Description: Initial Site Inspection by HD
Date Completed: 9/3/2014
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 9/2/2014
Disposition: DONE
Description: Stormwater Review-U
Date Completed: 9/2/2014
Disposition: DONE
Description: Case Entered "P"
Date Completed: 8/8/2014
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: ONGOING MONITORING
Wording H - AS PER WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 ALL ONSITE SEWAGE SYSTEMS REQUIRE THAT A RESTRICTIVE COVENANT REGARDING THE MONITORING OF THE ONSITE SEPTIC SYSTEM BE RECORDED TO THE PROPERTY TITLE. THE PROPERTY OWNER SHALL ASSURE THAT MONITORING IS PROVIDED BY AN APPROVED ENTITY AT THE FREQUENCY DEFINED PER STATE WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED. A COPY OF THE RECORDED OPERATIONS AND MONITORING AGREEMENT IS REQUIRED PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL PERMIT

Title: pressure test observation
Wording Health Dept. required to observe pressure test with system designer when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: SAND LINED TRENCH/BED
Wording TRENCH TO BE EXCAVATED TO 40" DEPTH AND THEN BACKFILLED WITH 12" OF ASTM 33 TYPE SAND AS PER DESIGN.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: minimum land area waiver
Wording This site has been granted a waiver from WAC 246-272A and JC Code 8.15 under Jefferson County Policy 97-2. The site requires a minimum land area of 15000sq/ft, the property has 12587sq/ft available on the site. Compliance with conditions of the waiver are required, a maximum of 377gallons of waste water per day can be applied to the site.

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet.

Title: System Capacity-no ADU
Wording This system as designed and approved is sized for only one single family residence. It is not sized for an Accessory Dwelling Unit (ADU). The minimum daily design flow per residence is 240 GPD.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: VIOLATION-limited permit life
Wording This permit was issued to correct a violation of WAC 246-272A for installation of a septic system w/o a permit. The permit must be completed within 90 days of the date of issuance.

Title: O & M Manual required
Wording Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS.

Title: Installation Inspection
Wording Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start.

Title: No Building Permit Guaranteed
Wording Approval/issuance of a sewage disposal permit or installation of a septic system does not guarantee the approval of other development or a building permit on this site. Future buildings that require connection to an on-site sewage system (OSS) shall only be approved if the OSS meets the current standards and codes in effect at the time of the building application.

Title: NO SHOOTING AREA
Wording This parcel is within a no shooting area per JCC 8.50.

Title: Code Compliance
Wording All construction and development activities must comply with all permit conditions, Washington State and Jefferson County Codes and Recommended Standards and Guidance documents in effect when the permit is issued.

Title: SITE PLAN CHANGES
Wording The site plan as submitted with the Sewage Disposal Application on July 20, 2014 has been reviewed for consistency under the UDC, and has been approved by Jefferson County Department of Community Development. Any modifications, changes, and/or additions to the stamped, approved site plan dated September 10, 2014 shall be resubmitted for review and approval by Jefferson County Department of Community Development.

Title: APPROVAL FOR ______ONLY
Wording This approval is for an on site sewage disposal system only. Any future permits on this site are subject to review for consistency with applicable codes and ordinances and does not preclude review and conditions which may be placed on future permits.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: Connection to Public Water
Wording This approval is valid only with a connection to an approved public water supply.