Permit Case Summary

Case Number: Search Help

Case Number:SEP2014-00083 Case Status:Finaled Date Received:6/18/2014
Description:SEP85-17 (failed) and filed here Date Issued:9/2/2014
Applicant: THE POINTE CORP Expiration Date:12/2/2014 12:00:00 AM
Site Address:54 EVERGREEN LN Case Finaled:10/1/2014
Parcel No:998300018 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 10/1/2014
Disposition: DONE
Description: Monitoring Agreemt Sent (Fm)
Date Completed: 9/22/2014
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed: 9/18/2014
Disposition: DONE
Description: Issue permit (Fm) "A"
Date Completed: 9/2/2014
Disposition: DONE
Description: Septic Permit Application (Fm)
Date Completed: 6/20/2014
Disposition: DONE
Description: Asbuilt drawing submitted
Date Completed: 10/1/2014
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 7/7/2014
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 9/2/2014
Disposition: DONE
Description: Case Entered "P"
Date Completed: 6/19/2014
Disposition:
Description: Stormwater Review-U
Date Completed: 9/2/2014
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: ONGOING MONITORING
Wording H - AS PER WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 ALL ONSITE SEWAGE SYSTEMS REQUIRE THAT A RESTRICTIVE COVENANT REGARDING THE MONITORING OF THE ONSITE SEPTIC SYSTEM BE RECORDED TO THE PROPERTY TITLE. THE PROPERTY OWNER SHALL ASSURE THAT MONITORING IS PROVIDED BY AN APPROVED ENTITY AT THE FREQUENCY DEFINED PER STATE WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED. A COPY OF THE RECORDED OPERATIONS AND MONITORING AGREEMENT IS REQUIRED PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL PERMIT

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: conventional-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the Designer is required prior to final approval.

Title: riser on d-box
Wording Distribution boxes shall be fitted with a riser to grade, constructed of durable materials and a secured lid, adequately sized to allow visible inspection of the liquid level in the box.

Title: VIOLATION-limited permit life
Wording This permit was issued to correct a violation of WAC 246-272A FOR A FAILED DRAINFIELD. The permit must be completed within 90 days of the date of issuance.

Title: O & M Manual required
Wording Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS.

Title: Installation Inspection
Wording Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start.

Title: Code Compliance
Wording All construction and development activities must comply with all permit conditions, Washington State and Jefferson County Codes and Recommended Standards and Guidance documents in effect when the permit is issued.

Title: EXISTING DRAINFIELD
Wording BOTH ENDS OF ALL EXISTING LATERALS MUST BE LOCATED PRIOR TO INSTALLING THE NEW LATERALS

Title: EXISTING ST
Wording If the existing tank is kept it must be certified by the designer to meet code in all aspects.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.