Permit Case Summary

Case Number: Search Help

Case Number:SEP2013-00108 Case Status:Finaled Date Received:9/17/2013
Description:SEP80-238 no longer valid and filed here. Date Issued:12/17/2013
Applicant:KINNAN MURRAY Expiration Date:12/17/2016 12:00:00 AM
Site Address:11 S 7TH AVE Case Finaled:5/24/2014
Parcel No:942900701 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: File Archived
Date Completed: 8/6/2018
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 5/24/2014
Disposition: DONE
Description: Monitoring Agreemt Sent (Fm)
Date Completed: 5/5/2014
Disposition: DONE
Description: Issue permit (Fm) "A"
Date Completed: 12/17/2013
Disposition: DONE
Description: Pending letter; add inf (Fm)
Date Completed: 12/17/2013
Disposition: DONE
Description: DCD Review Time
Date Completed: 10/3/2013
Disposition: PEND
Description: Additional Info Request-DRD
Date Completed: 12/16/2013
Disposition: DONE
Description: Septic Permit Application (Fm)
Date Completed: 12/3/2013
Disposition: DONE
Description: Pressure test required
Date Completed: 3/14/2014
Disposition: DONE
Description: Asbuilt drawing submitted
Date Completed: 4/24/2014
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 10/3/2013
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 12/16/2013
Disposition: DONE
Description: Case Entered "P"
Date Completed: 9/17/2013
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: ONGOING MONITORING
Wording H - AS PER WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 ALL ONSITE SEWAGE SYSTEMS REQUIRE THAT A RESTRICTIVE COVENANT REGARDING THE MONITORING OF THE ONSITE SEPTIC SYSTEM BE RECORDED TO THE PROPERTY TITLE. THE PROPERTY OWNER SHALL ASSURE THAT MONITORING IS PROVIDED BY AN APPROVED ENTITY AT THE FREQUENCY DEFINED PER STATE WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED. A COPY OF THE RECORDED OPERATIONS AND MONITORING AGREEMENT IS REQUIRED PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL PERMIT

Title: pressure test observation
Wording Health Dept. required to observe pressure test with system designer when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required and must comply with code at the time of application for use.

Title: Tank Abandonment
Wording H - Existing tank shall be properly abandoned. It shall be pumped and filled with clean fill. Documentation to be provided to Health Dept. prior to final.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: surface water setback
Wording Setback to surface waters- 100' required from drainfield and reserve areas. 50' required from tanks.

Title: protective barriers
Wording H - Permanent barriers are required along/around primary drainfield area to protect from parking, driving, and other land disturbing activities prior to final.

Title: O & M Manual required
Wording Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS.

Title: Installation Inspection
Wording Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start.

Title: Certified Installer Required
Wording This system must be constructed by an installer certified by the Jefferson County Public Health Department per state code WAC246-272A-0250.

Title: Code Compliance
Wording All construction and development activities must comply with all permit conditions, Washington State and Jefferson County Codes and Recommended Standards and Guidance documents in effect when the permit is issued.

Title: EXISTING SYSTEM
Wording The existing septic system was not finalled and does not meet current code. No future building permits will be approved until a new septic system is installed on the property.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: Connection to Public Water
Wording This approval is valid only with a connection to an approved public water supply.