Permit Case Summary

Case Number: Search Help

Case Number:SEP2013-00097 Case Status:Finaled Date Received:8/15/2013
Description:RE-ROUTE 4" TRANSPORT LINE. SEP07-331 valid and filed here. Date Issued:9/13/2013
Applicant:TODD SHOLD Expiration Date:9/13/2016 12:00:00 AM
Site Address:61 A RANDOLPH ST Case Finaled:3/26/2014
Parcel No:994800303 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 3/26/2014
Disposition: DONE
Description: Issue permit (Fm) "A"
Date Completed: 9/13/2013
Disposition: DONE
Description: Up Front Review
Date Completed: 9/3/2013
Disposition: DONE
Description: Septic Permit Application (Fm)
Date Completed: 8/15/2013
Disposition: DONE
Description: Asbuilt drawing submitted
Date Completed: 3/26/2014
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 9/13/2013
Disposition: DONE
Description: Stormwater Review-U
Date Completed: 9/13/2013
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 9/3/2013
Disposition: DONE
Description: Case Entered "P"
Date Completed: 8/15/2013
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: transport line double cased
Wording Any portion of transport line under a driven way is to be sleeved/cased or equivalent.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet. REQUIRED ON BOTH TANKS.

Title: conventional-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the Designer is required prior to final approval.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS.

Title: Installation Inspection
Wording Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start.

Title: NO SHOOTING AREA
Wording This parcel is within a no shooting area per JCC 8.50.

Title: Code Compliance
Wording All construction and development activities must comply with all permit conditions, Washington State and Jefferson County Codes and Recommended Standards and Guidance documents in effect when the permit is issued.

Title: GEOTECH-NO HOLD
Wording A Geotechnical Report was submitted in conjunction with the SPAAD application MLA09-00034. The report addressed the stability of the geologic hazard area as follows; a buffer of 15 feet shall be measured perpendicularly from the top or toe of the geologic hazard to the proposed single family residence. Jefferson County Code 18.22.170(5)(g) a building setback line is required from the edge of any buffer area. A total of 20 feet from the top of slope is required.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.