Permit Case Summary

Case Number: Search Help

Case Number:SEP2009-00091 Case Status:Finaled Date Received:7/28/2009
Description:lot 7 and N1/2 6. info from SEP78-152 filed to this case. tank to serve satelite bedroom Date Issued:9/25/2009
Applicant:PATRICIA COPELAND Expiration Date:9/25/2012 12:00:00 AM
Site Address:71 RANDOLPH ST Case Finaled:9/22/2011
Parcel No:989400206 Other Cases Parcel Data Map It More Details

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 9/22/2011
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed:
Disposition:
Description: Monitoring Agreemt Sent (Fm)
Date Completed: 11/12/2010
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed:
Disposition:
Description: Monitoring Agreemt Sent (Fm)
Date Completed: 9/25/2009
Disposition: DONE
Description: Issue permit (Fm) "A"
Date Completed: 9/25/2009
Disposition: DONE
Description: Pending letter; add inf (Fm)
Date Completed: 9/25/2009
Disposition: DONE
Description: Document Recorded
Date Completed: 8/13/2009
Disposition: DONE
Description: Septic Permit Application (Fm)
Date Completed: 7/28/2009
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 7/28/2009
Disposition:
Description: Case Entered "P"
Date Completed: 7/28/2009
Disposition:
Description: Stormwater Review-U
Date Completed: 8/25/2009
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 8/25/2009
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 8/13/2009
Disposition: DONE
Description: Asbuilt drawing submitted
Date Completed: 1/25/2011
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: ONGOING MONITORING
Wording H - AS PER WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 ALL ONSITE SEWAGE SYSTEMS REQUIRE THAT A RESTRICTIVE COVENANT REGARDING THE MONITORING OF THE ONSITE SEPTIC SYSTEM BE RECORDED TO THE PROPERTY TITLE. THE PROPERTY OWNER SHALL ASSURE THAT MONITORING IS PROVIDED BY AN APPROVED ENTITY AT THE FREQUENCY DEFINED PER STATE WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED. A COPY OF THE RECORDED OPERATIONS AND MONITORING AGREEMENT IS REQUIRED PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL PERMIT

Title: pressure test observation
Wording Health Dept. required to observe pressure test with system designer when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required. Water line will need to be moved to maintain 10' setback from reserve area at time of application for use. The pond being constructed by the owner will need to be moved at time of application for use of the reserve area.

Title: dose counter & ETM
Wording Dose counter and elapsed time meter are required in the control panel for all system components.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: minimum land RESTRICTIVE COV
Wording H - This permit is granted based on the recorded RESTRICTIVE COVENANT combining lots 6 N 1/2 and 7 of block 2 Port Hadlock to meet the minimum land area required under WAC 246-272A Onsite Sewage Code. COVENANT recorded 9/2/09, #AFN546270.

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet.

Title: conventional-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the Designer is required prior to final approval.

Title: riser on d-box
Wording Distribution boxes shall be fitted with a riser to grade, constructed of durable materials and a secured lid, adequately sized to allow visible inspection of the liquid level in the box.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: PUMP CHAMBER
Wording Pump chamber shall be equipped with a control panel outside within line of sight of the pump chamber. The panel shall have an audio and visual alarm, a cycle counter and a riser to grade. It shall be UL listed and meet L&I requirements.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS.

Title: Installation Inspection
Wording Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start.

Title: SATELITE BEDROOM-NO HOLD
Wording This permit is for a tank to serve a structure containing a "satelite" bedroom. The structure is not approved for kitchen facilities nor is it classified as an accessory dwelling unit. An application for "Change of use", further review and compliance with current code will be required prior to further alteration of the structure.

Title: SCREENED PUMP VAULT-HOLD
Wording H - A screened pump vault is required to reduce the discharge of solids to the existing drainfield.

Title: # OF BEDROOMS-HOLD
Wording H - The existing residence shall be inspected by Jefferson County Building Department to confirm the number of bedrooms. The number of bedrooms allowed int he primary residence is two. Modifications shall be made if necessary to alter the structure to 2 bedrooms to allow the addition of a satelite bedroom in a detached structure prior to final approval.


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: F-Confirmed ESAs
Wording The application was reviewed by the Jefferson County staff for the potential presence of Environmentally Sensitive Areas (ESAs) under the provisions of the Unified Development Code (UDC). After an initial Geographic Information Systems mapping review and an investigative site inspection, the following ESAs were confirmed to be present on the subject property: Critical Aquifer Recharge area with susceptible soils.