Permit Case Summary

Case Number: Search Help

Case Number:SEP2008-00192 Case Status:Finaled Date Received:9/12/2008
Description:lot 49. info from failed SEP85-9 filed here. Date Issued:9/24/2008
Applicant:HAZLI KATSIKAPES Expiration Date:12/24/2008 12:00:00 AM
Site Address:241 CHIMACUM CREEK DR Case Finaled:10/30/2008
Parcel No:943700050 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: Sanit. Survey Complt. by JCPH
Date Completed: 8/4/2009
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 10/30/2008
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed:
Disposition:
Description: Monitoring Agreement Sent
Date Completed: 9/24/2008
Disposition: DONE
Description: Issue permit (F)
Date Completed: 9/24/2008
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 9/12/2008
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 9/12/2008
Disposition:
Description: Case Entered
Date Completed: 9/12/2008
Disposition:
Description: Stormwater Review-U
Date Completed: 9/24/2008
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 9/24/2008
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 9/3/2008
Disposition: DONE
Description: Asbuilt drawing submitted
Date Completed: 10/30/2008
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: ONGOING MONITORING
Wording H - AS PER WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 ALL SYSTEMS REQUIRE MONITORING. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING AGREEMENT RECORDED TO THE PROPERTY TITLE PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: trench depth
Wording MAXIMUM TRENCH DEPTH 36 INCHES

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED PER JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED.

Title: conventional-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the Designer is required prior to final approval.

Title: riser on d-box
Wording Distribution boxes shall be fitted with a riser to grade, constructed of durable materials and a secured lid, adequately sized to allow visible inspection of the liquid level in the box.

Title: System Capacity-no ADU
Wording This system as designed and approved is sized for only one single family residence. It is not sized for an Accessory Dwelling Unit (ADU). The minimum daily design flow per residence is 240 GPD.

Title: VIOLATION-limited permit life
Wording This permit was issued to correct a violation of WAC 246-272A. The permit must be completed within 90 days of the date of issuance.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS.

Title: Installation Inspection
Wording Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start.


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: F-Confirmed ESAs
Wording The application was reviewed by the Jefferson County staff for the potential presence of Environmentally Sensitive Areas (ESAs) under the provisions of the Unified Development Code (UDC). After an initial Geographic Information Systems mapping review and an investigative site inspection, the following ESAs were confirmed to be present on the subject property: Critical aquifer recharge area-susceptible.