Permit Case Summary

Case Number: Search Help

Case Number:SEP2008-00161 Case Status:Finaled Date Received:7/28/2008
Description:now filed w/ SEP18-135 Tanks only Date Issued:8/29/2008
Applicant: SUNFIELD EDUCATION ASSOCIATION Expiration Date:8/29/2011 12:00:00 AM
Site Address:111 SUNFIELD LN Case Finaled:8/13/2009
Parcel No:901034003 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 8/13/2009
Disposition: DONE
Description: Pressure test required
Date Completed: 8/13/2009
Disposition: DONE
Description: Monitoring Agreement Sent
Date Completed: 9/3/2008
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed:
Disposition:
Description: Issue permit (F)
Date Completed: 8/29/2008
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 7/28/2008
Disposition:
Description: Septic Permit Application (F)
Date Completed: 7/28/2008
Disposition: DONE
Description: Case Entered
Date Completed: 7/28/2008
Disposition:
Description: Stormwater Review-U
Date Completed: 8/29/2008
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 8/29/2008
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 8/5/2008
Disposition: DONE
Description: Asbuilt drawing submitted
Date Completed: 9/9/2008
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pressure test observation
Wording Health Dept. required to observe a pump test with system designer when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: well setback requirement
Wording Setbacks to all wells- 50' required from tanks and effluent transport lines.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be sleeved/cased or equivalent.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength wastewater only. Disposal of any other waste strength is considered a violation of this permit.

Title: design flow/water usage monitorin
Wording Exceeding the average flow 1720 gal/day or the peak design flow for any one day f 2295 gal/day shall constitute a violation of this permit. Water usage monitoring shall be conducted monthly. These monitoring results shall be submitted to the Jefferson County Health Dept. no less than quarterly.

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: PUMP CHAMBER
Wording Pump chamber shall be water tight and a minimum capacity of 41 gal per design. It shall be equipped with a control panel outside within line of sight of the pump chamber. The panel shall have an audio and visual alarm, a cycle counter and a riser to grade. It shall be UL listed and meet L&I requirements.

Title: SCREEN REQUIRED
Wording A screen shall be provided at the outlet of the septic tank.

Title: System capacity/uses
Wording Approval of this permit does not assure the existing septic system has capacity for all uses allowed by current code.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS.

Title: Installation Inspection
Wording Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start.

Title: CERTIFIED INSTALLER-NO HOLD
Wording All components of the onsite sewage system must be installed by an installer certified by Jefferson County.