Case Number:SEP2008-00003 Case Status:Canceled Date Received:1/8/2008
Description:Botnen SP lot 2, Date Issued:10/20/2008
Applicant:ROGER BOTNEN Expiration Date:10/20/2011 12:00:00 AM
Site Address:10214 RHODY DR Case Finaled:
Parcel No:901112052 Other Cases Parcel Data Map It More Details

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: File Archived
Date Completed: 1/13/2016
Disposition: DONE
Description: Cancel/Expire applic "C"
Date Completed: 2/18/2014
Disposition: DONE
Description: Monitoring Agreement Sent
Date Completed: 10/20/2008
Disposition: DONE
Description: Issue permit (F)
Date Completed: 10/20/2008
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 3/14/2008
Disposition:
Description: REDESIGN SUBMITTED (F)
Date Completed: 10/20/2008
Disposition: DONE
Description: Pending letter; add inf (F)
Date Completed: 10/20/2008
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 1/8/2008
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 1/8/2008
Disposition:
Description: Case Entered
Date Completed: 1/8/2008
Disposition:
Description: Stormwater Review-U
Date Completed: 2/15/2008
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 2/15/2008
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 2/6/2008
Disposition: DONE
Description: Asbuilt drawing submitted
Date Completed:
Disposition:
Description: Pressure test required
Date Completed:
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: ONGOING MONITORING
Wording H - AS PER WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 ALL SYSTEMS REQUIRE MONITORING. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING AGREEMENT RECORDED TO THE PROPERTY TITLE PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test with system designer when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter & ETM
Wording Dose counter and elapsed time meter are required in the control panel for all system components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be sleeved/cased or equivalent.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: SAND LINED TRENCH/BED
Wording TRENCH TO BE EXCAVATED TO 48" DEPTH AND THEN BACKFILLED WITH ASTM 33 TYPE SAND TO 24" AND UP SIDE WALLS AS PER DESIGN.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: env. sensitive area conditions
Wording Compliance with the Environmentally Sensitive Areas Review conditions is required.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED PER JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED.

Title: surface water setback
Wording Setback to surface waters- 100' required from drainfield and reserve areas. 50' required from tanks.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: O & M Manual required
Wording Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS.

Title: Installation Inspection
Wording Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start.

Title: ANTISIPHON DEVICE-NO HOLD
Wording An anti-siphon device is required if the drainfield laterals are at a lower elevation than the pump chamber.

Title: Wetland Setback
Wording Based on the report submitted delineating the wetland a setback of 100-feet, measured perpendicularly from the wetland edge, shall be permanently maintained as a buffer. No filling, grading, clearing, or other alteration of the wetland or its buffer is allowed.

Title: Identify Wetland Buffer
Wording A permanent physical separation along the upland boundary of the wetland buffer area shall be installed and permanently maintained. Such separation can include installing logs, trees, a hedgerow, or any other prominent physical marking approved by the UDC Administrator.

Title: Mark Wetland Buffer Drng Cnstrctn
Wording Buffer perimeters shall be marked with temporary signs at an interval of one per parcel or every one hundred (100) feet, whichever is less. Signs shall contain the following statement: "Wetland & Buffer - Do Not Remove or Alter Existing Vegetation."


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: F-Confirmed ESAs
Wording The application was reviewed by the Jefferson County staff for the potential presence of Environmentally Sensitive Areas (ESAs) under the provisions of the Unified Development Code (UDC). After an initial Geographic Information Systems mapping review and an investigative site inspection, the following ESAs were confirmed to be present on the subject property: wetland, seismic hazard, critical aquifer recharge area with susceptible soils.