Case Number:SEP2007-00331 Case Status:Finaled Date Received:9/28/2007
Description:filed w/ SEP13-97 (transport mod) Date Issued:6/21/2008
Applicant:TODD SHOLD Expiration Date:6/21/2011 12:00:00 AM
Site Address:61 RANDOLPH ST Case Finaled:9/13/2011
Parcel No:994800303 Other Cases Parcel Data Map It More Details

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: File Archived
Date Completed: 8/23/2013
Disposition: DONE
Description: Close Case/Retrn status to "F"
Date Completed: 8/23/2013
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 9/13/2011
Disposition: DONE
Description: Monitoring Agreemt Sent (Fm)
Date Completed: 9/6/2011
Disposition:
Description: INSTALLATION START NOTICE
Date Completed: 8/29/2011
Disposition: DONE
Description: Issue permit (F)
Date Completed: 6/21/2008
Disposition: DONE
Description: Additional Info Request-U
Date Completed: 5/13/2008
Disposition: DONE
Description: Additional Info Request-U
Date Completed: 5/22/2008
Disposition: DONE
Description: Det. of Completeness-UF
Date Completed: 11/27/2007
Disposition: DONE
Description: Pending letter; add inf (F)
Date Completed: 6/21/2008
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 9/28/2007
Disposition:
Description: Septic Permit Application (F)
Date Completed: 9/28/2007
Disposition: DONE
Description: Case Entered
Date Completed: 9/28/2007
Disposition:
Description: Stormwater Review-U
Date Completed: 6/21/2008
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 5/22/2008
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 10/12/2007
Disposition: DONE
Description: Asbuilt drawing submitted
Date Completed: 9/13/2011
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: other setbacks req.
Wording 30 ft. setback from bank to be maintained.

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED PER JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED.

Title: conventional-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the Designer is required prior to final approval.

Title: riser on d-box
Wording Distribution boxes shall be fitted with a riser to grade, constructed of durable materials and a secured lid, adequately sized to allow visible inspection of the liquid level in the box.

Title: System Capacity-no ADU
Wording This system as designed and approved is sized for only one single family residence. It is not sized for an Accessory Dwelling Unit (ADU). The minimum daily design flow per residence is 240 GPD.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: O & M Manual required
Wording Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS.

Title: Installation Inspection
Wording Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start.

Title: SDP CONDITION
Wording The septic system will be constructed within shoreline jurisdiction, and a shoreline permit is required from Jefferson County Department of Community Development to construct the septic system.

Title: Landslide Vegetative Buffer
Wording A vegetative buffer of 30-feet shall be permanently maintained from the top or edge of the Landslide Hazard Area. All buffers shall be measured perpendicularly from the top or toe of the Landslide Hazard Area.

Title: Geotech Report Submitted
Wording A Geotechnical Report was submitted in conjunction with this application. The report addressed the stability of the geologic hazard area. A setback of 15-feet shall be measured perpendicularly from the top or toe of the geologic hazard to the proposed (indicate type of development).

Title: Slide Buffer-Native Vegetation
Wording Landslide Hazard Areas and their associated buffers shall remain naturally vegetated. Should buffer disturbance occur during construction, the Unified Development Code (UDC) Administrator shall require replanting with native vegetation. No alterations shall be made to the Landslide Hazard Area or its associated buffer without prior authorization by the UDC Administrator.

Title: Identify Landslide Hazard Buffer
Wording Prior to and during approved construction activities, the perimeter of the landslide hazard area buffer shall be marked with a temporary sign. The sign shall be placed in such a manner that it can be directly observed from the construction area. The sign shall contain the following statement: "Landslide Hazard Area and Buffer - Do not Remove or Alter Existing Vegetation."

Title: Permanent Landslide Boundary
Wording The applicant shall permanently separate the boundary of the Landslide Hazard Area Buffer from the remainder of the subject property through installing logs, trees, a hedge row, or any other prominent physical marking approved by the UDC Administrator.

Title: Aquifer Recharge Conditions (SFR)
Wording Critical Aquifer Recharge Areas may require special protection measures to mitigate water quality degradation. The submitted proposal does not require additional aquifer protection measures. However, during construction the project shall follow the Best Management Practices (BMPs) and facility design standards as identified and defined in the Stormwater Management Manual for the Puget Sound Basin.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: F-Confirmed ESAs
Wording The application was reviewed by the Jefferson County staff for the potential presence of Environmentally Sensitive Areas (ESAs) under the provisions of the Unified Development Code (UDC). After an initial Geographic Information Systems mapping review, the following ESAs were confirmed to be present on the subject property: urban shoreline designation, geologically hazardous areas (unstable shoreline slope stability, seismic, and landslide), fish and wildlife hatitat (purple martin), susceptible aquifer recharge area, coastal seawater intrusion protection zone.

Title: F-Geohazard Area
Wording Geologically Hazardous Areas in Jefferson County are characterized by slope, soil type, geologic material, and groundwater that may combine to create problems with slope stability, erosion, and water quality during and after construction or during natural events such as earthquakes or severe rainstorms.

Title: F-SIPZ
Wording Marine shorelines and islands are susceptible to a condition that is known as seawater intrusion. Seawater intrusion is a condition in which the saltwater/freshwater interface in an aquifer moves inland so that wells drilled on upland areas cannot obtain freshwater suitable for public consumption without significant additional treatment and cost. Maintaining a stable balance in the saltwater/freshwater interface is primarily a function of the rate of aquifer recharge (primarily through rainfall) and the rate of groundwater withdrawals (primarily through wells). The Washington Department of Ecology is the agency with statutory authority to regulate groundwater withdrawal for individual wells in Jefferson County. New development, redevelopment, and land use activities on islands and in close proximity to marine shorelines in particular should be developed in such a manner to maximize aquifer recharge and maintain the saltwater/freshwater balance to the maximum extent possible by infiltrating stormwater runoff so that it recharges the aquifer.

Title: F-Coastal SIPZ
Wording The parcel is located within a coastal SIPZ (seawater intrusion protection zone) according to the County GIS map. There are voluntary and mandatory measures identified in the Jefferson County Seawater Intrusion Policy (Resolution 44-22, effective September 23, 2002) that apply to well drilling proposals and building permit applications on existing lots of record. A Coastal SIPZ is defined as: all islands and area within one-quarter mile of marine shoreline, but no history of chloride concentration above 100 mg/L in groundwater sources within 1000 feet.