Permit Case Summary

Case Number: Search Help

Case Number:SEP2007-00327 Case Status:Finaled Date Received:9/20/2007
Description:SEP73-160 abandoned in favor of this permit & filed here SEP71-93 also on parcel Date Issued:2/22/2008
Applicant:WILLIAM MORAN Expiration Date:2/22/2011 12:00:00 AM
Site Address:62 W FITCHBURG AVE Case Finaled:2/9/2011
Parcel No:952800803 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 2/9/2011
Disposition: DONE
Description: Monitoring Agreemt Sent (Fm)
Date Completed: 8/23/2010
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed: 8/2/2010
Disposition: DONE
Description: Issue permit (F)
Date Completed: 2/22/2008
Disposition: DONE
Description: Pending letter; add inf (F)
Date Completed: 2/22/2008
Disposition: DONE
Description: Pending letter; add inf (F)
Date Completed: 2/22/2008
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 9/20/2007
Disposition:
Description: Case Entered
Date Completed: 9/20/2007
Disposition:
Description: Env. Sensitive Area Review-U
Date Completed: 10/4/2007
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 9/26/2007
Disposition: DONE
Description: Asbuilt drawing submitted
Date Completed: 2/10/2011
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: trench depth
Wording MINIMUM TRENCH DEPTH 24 TO 30 INCHES AS NEEDED TO REACH SANDS

Title: well decommissioning
Wording H - Well to be decommissioned as per WAC 173-160-381 by licensed well driller. Contact Jefferson County Public Health for information on required applications and inspections. Verification of decommissioning to be provided to Public Health Department. COMPLETE USR10-47 (F) Final approval of this septic permit requires proper deommissioning of the well.

Title: Tank Abandonment
Wording H - Existing tank shall be properly abandoned. It shall be pumped and filled with clean fill. Documentation to be provided to Health Dept. prior to final.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: minimum land RESTRICTIVE COV
Wording H - This permit is granted based on the recorded RESTRICTIVE COVENANT combining lots to meet the minimum land area required under WAC 246-272A Onsite Sewage Code. COVENANT recorded under AFN 529859

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED PER JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED.

Title: conventional-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the Designer is required prior to final approval.

Title: riser on d-box
Wording Distribution boxes shall be fitted with a riser to grade, constructed of durable materials and a secured lid, adequately sized to allow visible inspection of the liquid level in the box.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: O & M Manual required
Wording Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS.

Title: Installation Inspection
Wording Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.