Permit Case Summary

Case Number: Search Help

Case Number:SEP2007-00213 Case Status:Finaled Date Received:6/25/2007
Description:SEP81-149 now filed here. system serves dog grooming facility and caretaker quarters. EES 2/23/09 Date Issued:8/30/2007
Applicant:JEFFREY SHAFFETT Expiration Date:8/30/2008 12:00:00 AM
Site Address:816 CHIMACUM RD Case Finaled:3/28/2008
Parcel No:901111011 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 3/28/2008
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed:
Disposition:
Description: Monitoring Agreement Sent
Date Completed: 2/13/2008
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed: 2/21/2008
Disposition: DONE
Description: Issue permit (F)
Date Completed: 8/30/2007
Disposition: DONE
Description: Redesign Submitted no form
Date Completed: 8/8/2007
Disposition: DONE
Description: Pending letter; add inf (F)
Date Completed: 8/30/2007
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 6/25/2007
Disposition:
Description: Septic Permit Application (F)
Date Completed: 6/25/2007
Disposition: DONE
Description: Case Entered
Date Completed: 6/25/2007
Disposition:
Description: Stormwater Review-U
Date Completed: 7/9/2007
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 7/9/2007
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 7/9/2007
Disposition: DONE
Description: Asbuilt drawing submitted
Date Completed: 3/28/2008
Disposition: DONE
Description: Pressure test required
Date Completed: 3/12/2008
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: ONGOING MONITORING
Wording H - AS PER WAC 246-272 AND JEFFERSON COUNTY CODE 8.15 ALL SYSTEMS REQUIRE MONITORING. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING AGREEMENT RECORDED TO THE PROPERTY TITLE PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test with system designer when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: Tank Abandonment
Wording H - Existing tank shall be properly abandoned. It shall be pumped and filled with clean fill. Documentation to be provided to Health Dept. prior to final.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: SAND LINED BED
Wording BED TO BE EXCAVATED TO 36" DEPTH AND THEN BACKFILLED WITH ASTM 33 TYPE SAND TO 24" AND UP SIDE WALLS AS PER DESIGN.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength wastewater only. Disposal of any other waste strength is considered a violation of this permit.

Title: design flow/water usage monitorin
Wording Exceeding the permitted design flow of 360 gal/day shall constitute a violation of this permit. Water usage monitoring shall be conducted weekly. for the first 6 month then quarterly. These monitoring results shall be submitted to the Jefferson County Health Dept. annually.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED PER JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: VIOLATION-limited permit life
Wording The current systemis in the process of failing but has not surfaced. This permit must be completed within 360 days of the date of issuance or immediatly if sewage backs up in the business or surfaces.

Title: SCREEN REQUIRED
Wording A screen shall be provided at the outlet of the septic tank and should be provided around the pump. This will help protect against animal hair from entering the drainfield.

Title: O & M Manual required
Wording Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system.

Title: System capacity/uses
Wording Approval of this permit does not assure the septic system has capacity for all uses allowed by current code.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation.

Title: ANIMAL HAIR
Wording Animal hair must be traped and/or screened and prevented from entering the septic system. Failure to do so will lead to pre-mature failure of the septic system.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.