Permit Case Summary

Case Number: Search Help

Case Number:SEP2007-00134 Case Status:Finaled Date Received:4/20/2007
Description:system serves house and ADU. info from SEP03-252, and SEP03-253 EES's are filed to this case. Date Issued:6/19/2007
Applicant: PUGET SOUND ENERGY Expiration Date:6/19/2010 12:00:00 AM
Site Address:1164 CHIMACUM RD Case Finaled:5/21/2008
Parcel No:901113019 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 5/21/2008
Disposition: DONE
Description: Monitoring Agreement Sent
Date Completed: 9/25/2007
Disposition: DONE
Description: Issue permit (F)
Date Completed: 6/19/2007
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 4/20/2007
Disposition:
Description: Septic Permit Application (F)
Date Completed: 4/20/2007
Disposition: DONE
Description: Case Entered
Date Completed: 4/20/2007
Disposition:
Description: Stormwater Review-U
Date Completed: 6/7/2007
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 6/7/2007
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 5/11/2007
Disposition: DONE
Description: Asbuilt drawing submitted
Date Completed: 5/20/2008
Disposition: DONE
Description: Pressure test required
Date Completed: 9/20/2007
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: ONGOING MONITORING
Wording H - AS PER WAC 246-272 AND JEFFERSON COUNTY CODE 8.15 ALL SYSTEMS REQUIRE MONITORING. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT RECORDED TO THE PROPERTY TITLE PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM. While the County strongly recommends that the property owner allow inspectors to enter their property to inspect the system in order to insure that the system is functioning correctly, the property owner always has the right under the Fourth Amendment and our State Constitution, to refuse the inspectors access to their property. The property owner never loses the right to refuse access and can do so despite never having refused access before.

Title: pressure test observation
Wording Health Dept. required to observe pressure test with system designer when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required.

Title: well abandonment
Wording H - Well to be abandoned as per WAC 173-160-381 by licensed well driller. Notice to be provided to the Health Department prior to abandonment. Verification of abandonment to be provided to Health Department. See letter in file from Puget Sound Energy.

Title: Tank Abandonment
Wording H - Existing tank TO THE SOUTH OF THE ADU shall be properly abandoned. It shall be pumped and filled with clean fill. Documentation to be provided to Health Dept. prior to final. The existing tank that serves the ADU may be used only if it is leak tested and confirmed to be in good condition by the designer. Documentation shall be submitted with record/asbuilt drawing.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter
Wording Dose counter and elapsed time meter are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be sleeved/cased or equivalent.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: SAND LINED TRENCH/BED
Wording TRENCH TO BE EXCAVATED TO 48" DEPTH AND THEN BACKFILLED WITH ASTM 33 TYPE SAND TO 24" AND UP SIDE WALLS AS PER DESIGN.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength wastewater only. Disposal of any other waste strength is considered a violation of this permit.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED AT 6 MONTHS, AT ONE YEAR EVERY 3 YEARS THEREAFTER.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: O & M Manual required
Wording Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system.

Title: Designer Notification/inspections
Wording Designer must be contacted prior to start of construction and for inspections during installation.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: F-No ESAs Found
Wording The application was reviewed by Jefferson County staff for the presence of Environmentally Sensitive Areas (ESAs) and has concluded that the property DOES NOT contain Environmentally Sensitive Areas. Future proposals will be subject to a new ESA review and conditions may be added if ESAs are found on the property.