Permit Case Summary

Case Number: Search Help

Case Number:SEP2006-00205 Case Status:Finaled Date Received:6/23/2006
Description:lots 3 & 4 Date Issued:8/13/2006
Applicant:JAMES JACKSON Expiration Date:8/13/2009 12:00:00 AM
Site Address:31 2ND ST Case Finaled:3/21/2008
Parcel No:986400903 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: OSS Inspection-6 Months
Date Completed: 2/25/2010
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 3/21/2008
Disposition: DONE
Description: Asbuilt drawing submitted
Date Completed: 3/17/2008
Disposition: DONE
Description: Monitoring Agreement Sent
Date Completed: 3/11/2008
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed:
Disposition:
Description: Issue permit (F)
Date Completed: 8/13/2006
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 6/23/2006
Disposition:
Description: Septic Permit Application (F)
Date Completed: 6/23/2006
Disposition: DONE
Description: Case Entered
Date Completed: 6/23/2006
Disposition:
Description: Stormwater Review-U
Date Completed: 8/13/2006
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 8/13/2006
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 6/1/2006
Disposition: DONE
Description: Pressure test required
Date Completed: 3/11/2008
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording H - AS PER WAC 246-272 AND JEFFERSON COUNTY CODE 8.15 ALL SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM. While the County strongly recommends that the property owner allow inspectors to enter their property to inspect the system in order to insure that the system is functioning correctly, the property owner always has the right under the Fourth Amendment and our State Constitution, to refuse the inspectors access to their property. The property owner never loses the right to refuse access and can do so despite never having refused access before.

Title: pressure test observation
Wording Health Dept. required to observe pressure test when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording H - An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter
Wording Dose counter and elapsed time meter is required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: SAND LINED TRENCH/BED
Wording Care to be taken to adequately compact/settle ASTM sand prior to placement of drainrock where the depth of sand varies in the system.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: minimum land RESTRICTIVE COV
Wording H - This permit is granted based on the recorded RESTRICTIVE COVENANT combining lots 3 & 4 of block 9, Phillips Addition to Irondale to meet the minimum land area required under WAC 246-272 Onsite Sewage Code. COVENANT recorded 6/23/2006, #512590.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED AT 6 MONTHS, AT ONE YEAR AND ANNUALLY THEREAFTER.

Title: protective barriers
Wording H - Permanent barriers are required along/around primary and reserve drainfield areas to protect from parking, driving, and other land disturbing activities prior to final.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: O & M Manual required
Wording Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system.

Title: Designer Notification/inspections