Permit Case Summary

Case Number: Search Help

Case Number:SEP2005-00131 Case Status:Finaled Date Received:5/11/2005
Description:all info filed to repair/replacement SEP18-00197. info from SEP78-222 filed to this case. Date Issued:6/3/2005
Applicant:JOHN MC CLANE Expiration Date:9/3/2005 12:00:00 AM
Site Address:31 S 7TH AVE Case Finaled:7/8/2005
Parcel No:942900702 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: Sanit. Survey Complt. by JCPH
Date Completed: 11/2/2009
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 7/8/2005
Disposition: DONE
Description: Issue permit (F)
Date Completed: 6/3/2005
Disposition: DONE
Description: Issue permit (F)
Date Completed: 6/3/2005
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 5/11/2005
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 5/11/2005
Disposition:
Description: Case Entered
Date Completed: 5/11/2005
Disposition:
Description: Stormwater Review-U
Date Completed: 6/3/2005
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 6/3/2005
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 5/16/2005
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: Tank Abandonment
Wording Existing tank shall be properly abandoned. It shall be pumped and filled with clean fill. Documentation to be provided to Health Dept. prior to final.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED EVERY 3 YEARS.

Title: conventional-asbuilt required
Wording An asbuilt drawing and certification of completion by the installer is required prior to final approval.

Title: protective barriers
Wording Permanent barriers are required along/around primary and reserve drainfield areas to protect from parking, driving, and other land disturbing activities prior to final.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: VIOLATION-limited permit life
Wording This permit was issued to correct a violation of WAC 246-272. The permit must be completed within 90 days of the date of issuance.