Permit Case Summary

Case Number: Search Help

Case Number:SEP2004-00216 Case Status:Finaled Date Received:9/7/2004
Description:info from SEP74-188 filed with this repair, This site contains 3 onsite sewage systems SEP71-109, SEP88-0153, and SEP04-216 Date Issued:9/18/2004
Applicant:ROBERTA MEYER Expiration Date:12/18/2004 12:00:00 AM
Site Address:10424 RHODY DR Case Finaled:12/16/2004
Parcel No:901101010 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 12/16/2004
Disposition: DONE
Description: Issue permit (F)
Date Completed: 9/18/2004
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 9/8/2004
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 9/8/2004
Disposition:
Description: Case Entered
Date Completed: 9/8/2004
Disposition:
Description: Stormwater Review-U
Date Completed: 9/18/2004
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 9/18/2004
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 9/16/2004
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required.

Title: Tank Abandonment
Wording Existing tank shall be properly abandoned. It shall be pumped and filled with clean fill. Documentation to be provided to Health Dept. prior to final.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED EVERY 6 YEARS

Title: conventional-asbuilt required
Wording An asbuilt drawing and certification of completion by the Designer is required prior to final approval.

Title: riser on d-box
Wording Distribution boxes shall be fitted with a riser to grade, constructed of durable materials and a secured lid, adequately sized to allow visible inspection of the liquid level in the box.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: VIOLATION-limited permit life
Wording This permit was issued to correct a violation of WAC 246-272. The permit must be completed within 90 days of the date of issuance.

Title: NO. OF BEDROOMS-HOLD
Wording This system is permitted for only 2 bedrooms. The number of bedrooms in the house must be verified by the Jefferson County Building Official prior to final.


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: F-Confirmed ESAs
Wording The application was reviewed by the Jefferson County staff for the potential presence of Environmentally Sensitive Areas (ESAs) under the provisions of the Unified Development Code (UDC). After an initial Geographic Information Systems mapping review and an investigative site inspection, the following ESAs were confirmed to be present on the subject property: Critical Aquifer Recharge Area-Suceptible and Special.