Permit Case Summary

Case Number: Search Help

Case Number:SEP2003-00293 Case Status:Finaled Date Received:12/3/2003
Description:lot 21, this site is connected to community drainfield "C" SEP95-290 Date Issued:12/23/2003
Applicant: BRODERS INC Expiration Date:12/23/2006 12:00:00 AM
Site Address:364 PORT HADLOCK HEIGHTS RD Case Finaled:8/2/2004
Parcel No:989506121 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 8/2/2004
Disposition: DONE
Description: Issue permit (F)
Date Completed: 12/23/2003
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 12/4/2003
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 12/4/2003
Disposition:
Description: Case Entered
Date Completed: 12/4/2003
Disposition:
Description: Stormwater Review-U
Date Completed: 12/23/2003
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 12/23/2003
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 12/8/2003
Disposition: DONE
Description: Pressure test required
Date Completed: 7/29/2004
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pressure test observation
Wording Health Dept. required to observe pump test when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and pump chamber

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be sleeved/cased or equivalent.

Title: comm- sep tank inspection
Wording Health Department is to be contacted for a final inspection of the septic tank and pump chamber prior to covering.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED EVERY 3 YEARS.

Title: conventional-asbuilt required
Wording An asbuilt drawing and certification of completion by the Designer is required prior to final approval.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: PUMP CHAMBER
Wording Pump chamber shall be water tight and a minimum capacity of .... It shall be equipped with a control panel outside within line of sight of the pump chamber. The panel shall have an audio and visual alarm, a cycle counter and a riser to grade. It shall be UL listed and meet L&I requirements.

Title: SCREEN REQUIRED
Wording A screen shall be provided either at the outlet of the septic tank or around the pump or at both locations. A pump shroud is required if only an outlet baffle filter is used.