Permit Case Summary

Case Number: Search Help

Case Number:SEP2003-00267 Case Status:Finaled Date Received:10/21/2003
Description:LOT 20 connected to Sys. "C", SEP95-290 Date Issued:11/6/2003
Applicant: BRODERS INC Expiration Date:11/6/2006 12:00:00 AM
Site Address:356 PORT HADLOCK HEIGHTS RD Case Finaled:4/7/2004
Parcel No:989506120 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 4/7/2004
Disposition: DONE
Description: Issue permit (F)
Date Completed: 11/6/2003
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 10/21/2003
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 10/21/2003
Disposition:
Description: Case Entered
Date Completed: 10/21/2003
Disposition:
Description: Stormwater Review-U
Date Completed: 11/4/2003
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 11/4/2003
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 10/29/2003
Disposition: DONE
Description: Pressure test required
Date Completed: 4/5/2004
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pressure test observation
Wording Health Dept. required to observe operation of pump when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and pump chamber area.

Title: community df-tanks only
Wording Installer will verify with the system manager, and the designer for specifications of pump requirements and inspections required by either party.

Title: comm- sep tank inspection
Wording Health Department is to be contacted for a final inspection of the septic tank and pump chamber prior to covering.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet.

Title: conventional-asbuilt required
Wording An asbuilt drawing and certification of completion by the Designer is required prior to final approval.

Title: surface water setback
Wording Setback to surface waters- 50' required from tanks.

Title: protective barriers
Wording Permanent barriers are required along/around tanks to protect from parking, driving, and other land disturbing activities prior to final.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: PUMP CHAMBER
Wording Pump chamber shall be water tight and a minimum capacity of 750gal. It shall be equipped with a control panel outside within line of sight of the pump chamber. The panel shall have an audio and visual alarm, a cycle counter and a riser to grade. It shall be UL listed and meet L&I requirements.

Title: CONNECTION TO COMM-NO HOLD
Wording This lot 20 is connected to community drainfield SEP95-290 and is approved for 2 bedrooms.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.