Permit Case Summary

Case Number: Search Help

Case Number:SEP2003-00164 Case Status:Finaled Date Received:6/23/2003
Description:SEP80-152 NOW FILED HERE. SP 7/2/03 Date Issued:7/1/2003
Applicant:TERRY MCCULLOUGH Expiration Date:8/1/2003 12:00:00 AM
Site Address:11 PINE CT Case Finaled:7/7/2003
Parcel No:998300049 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 7/7/2003
Disposition: DONE
Description: Issue permit (F)
Date Completed: 7/1/2003
Disposition: DONE
Description: Case Entered
Date Completed: 6/23/2003
Disposition:
Description: Stormwater Review-U
Date Completed: 6/30/2003
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 6/30/2003
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 6/27/2003
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed:
Disposition:
Description: Print ESA Review Form-F
Date Completed: 6/23/2003
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: trench depth
Wording EXISTING TRENCHES INSTALLED AT 112/18 INCHES.

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: water tight tank
Wording Septic tank and pump chamber to be water tight. Extra protection (i.e. Bentonite) to be used around inlet, outlet, and risers due to high water table.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED EVERY 3 YEARS...

Title: conventional-asbuilt required
Wording An asbuilt drawing and certification of completion by the installer is required prior to final approval.

Title: riser on d-box
Wording Distribution boxes shall be fitted with a riser to grade, constructed of durable materials and a secured lid, adequately sized to allow visible inspection of the liquid level in the box.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: VIOLATION-limited permit life
Wording This permit was issued to correct a violation of WAC 246-272. The permit must be completed within 90 days of the date of issuance. Existing system was installed without a permit, this application is justifiying the use of the existing trenches and pump tank. Verification of pump function, control panel function and that septic tank has inlet and outlet baffles are required for the as-built.