Permit Case Summary

Case Number: Search Help

Case Number:SEP2003-00110 Case Status:Finaled Date Received:5/1/2003
Description:lots 3 & 4, site B Date Issued:6/12/2003
Applicant:CHRIS ADAMS Expiration Date:6/12/2006 12:00:00 AM
Site Address:93 W MONTGOMERY ST Case Finaled:4/19/2004
Parcel No:956700802 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 4/19/2004
Disposition: DONE
Description: Reinspection
Date Completed: 10/6/2003
Disposition: DONE
Description: Document Recorded
Date Completed: 7/3/2003
Disposition: DONE
Description: Issue permit (F)
Date Completed: 6/12/2003
Disposition: DONE
Description: Pending letter; add inf (F)
Date Completed: 6/12/2003
Disposition: DONE
Description: App Substantially Complete-U
Date Completed: 5/7/2003
Disposition: DONE
Description: Case Entered
Date Completed: 5/7/2003
Disposition:
Description: Stormwater Review-U
Date Completed: 6/12/2003
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 6/12/2003
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 3/25/2003
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 5/7/2003
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 5/7/2003
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: minimum land NOTICE TO TITLE
Wording This permit is granted based on the recorded RESTRICTIVE COVENANT combining lots 3 &4 of block 8, Harrisburg along with the vacated portion of Montomery St. to meet the minimum land area required under WAC 246-272 Onsite Sewage Code. COVENANT recorded 6/2/03., #470440

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED EVERY 3 YEARS.

Title: conventional-asbuilt required
Wording An asbuilt drawing and certification of completion by the installer is required prior to final approval.

Title: protective barriers
Wording Permanent barriers are required along/around primary and reserve drainfield areas to protect from parking, driving, and other land disturbing activities prior to final.

Title: riser on d-box
Wording Distribution boxes shall be fitted with a riser to grade, constructed of durable materials and a secured lid, adequately sized to allow visible inspection of the liquid level in the box.

Title: System Capacity-no ADU
Wording This system as designed and approved is sized for only one single family residence. It is not sized for an Accessory Dwelling Unit (ADU). The minimum daily design flow per residence is 240 GPD.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: RESERVE AREA-NO HOLD
Wording The reserve area was filled in 2003 with 3'-5' of fill. Use of the designated reserve will require removal of fill to place system in native undisturbed soil or use of an alternative system to reach native material.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: F-Confirmed ESAs
Wording The application was reviewed by the Jefferson County staff for the potential presence of Environmentally Sensitive Areas (ESAs) under the provisions of the Unified Development Code (UDC). After an initial Geographic Information Systems mapping review and an investigative site inspection, the following ESAs were confirmed to be present on the subject property:Special Aquifer Recharge Protection Areas on a portion of the lot.