Permit Case Summary

Case Number: Search Help

Case Number:SEP2003-00094 Case Status:Finaled Date Received:4/21/2003
Description:Filed to SEP07-170 & info from SEP02-85 filed with this case for expansion Date Issued:5/12/2003
Applicant:CAROL FLETCHER Expiration Date:5/12/2006 12:00:00 AM
Site Address:173 CHIMACUM RD Case Finaled:7/3/2003
Parcel No:901024005 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 7/3/2003
Disposition: DONE
Description: Issue permit (F)
Date Completed: 5/12/2003
Disposition: DONE
Description: App Substantially Complete-U
Date Completed: 4/23/2003
Disposition: DONE
Description: Case Entered
Date Completed: 4/23/2003
Disposition:
Description: Stormwater Review-U
Date Completed: 5/12/2003
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 5/12/2003
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 5/7/2003
Disposition: DONE
Description: Pressure test required
Date Completed:
Disposition:
Description: Print ESA Review Form-F
Date Completed: 4/23/2003
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 4/23/2003
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 AND JEFFERSON COUNTY CODE 8.15 ALL SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM. While the County strongly recommends that the property owner allow inspectors to enter their property to inspect the system in order to insure that the system is functioning correctly, the property owner always has the right under the Fourth Amendment and our State Constitution, to refuse the inspectors access to their property. The property owner never loses the right to refuse access and can do so despite never having refused access before.

Title: pressure test observation
Wording Health Dept. required to observe pressure test when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: trench depth
Wording Bottom of trench excavation for placement of sand shall be level and shall be a minimum of 6" into the suitable soil horizon, type 2A or type 1 soils.

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required.

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads.

Title: Tank Abandonment
Wording County records indicate one existing septic system SEP79-179 and per owner there is another septic system that does not have a county record. All existing tanks shall be properly abandoned. It shall be pumped and filled with clean fill. Documentation to be provided to Health Dept. prior to final.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be sleeved/cased or equivalent.

Title: community drainfield
Wording This community drainfield, serving more than one facility, will require a management and operations agreement with an entity approved by the Jefferson County Health Department as per Jefferson County Policy when/if the facilities are separately owned

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code and Building Code for other/future development on the site.

Title: minimum land NOTICE TO TITLE
Wording This permit is granted based on the recorded RESTRICTIVE COVENANT combining parcels 901-024-046, 901-024-048 and 901-024-005 to meet the minimum land area required under WAC 246-272 Onsite Sewage Code. COVENANT recorded 12-2-02, #462731.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength wastewater only. Disposal of any other waste strength is considered a violation of this permit.

Title: BOD-WASTE STRENGTH MONITORING
Wording Waste Strength (BOD, TSS, Grease and oils) will be required to be monitored if any proposed uses generate high strength waste. It will need to be monitored quarterly for the first year of operation and annually thereafter. Responsibility is that of the owner. Results are to be submitted to the Jefferson County Health Dept.

Title: design flow/water usage monitorin
Wording Exceeding the permitted design flow of 2300 gal/day shall constitute a violation of this permit. Water usage monitoring shall be conducted monthly at a minimum. These monitoring results shall be submitted to the Jefferson County Health Dept. no less than quarterly.

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED EVERY AT 6 MONTHS, AT ONE YEAR AND ANNUALLY THEREAFTER.

Title: protective barriers
Wording Permanent barriers are required along/around primary and reserve drainfield areas to protect from parking, driving, and other land disturbing activities prior to final.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: Setback - Drains
Wording A 30' setback shall be maintained from the disposal component and reserve area to any downslope footing, curtain or interceptor drain or drainage ditch.

Title: ROAD CROSSING PERMIT-NO HOLD
Wording This application includes a road crossing permit. Compliance with permit is required.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: F-No ESAs Found
Wording The application was reviewed by Jefferson County staff for the presence of Environmentally Sensitive Areas (ESAs) and has concluded that the property DOES NOT contain Environmentally Sensitive Areas. Future proposals will be subject to a new ESA review and conditions may be added if ESAs are found on the property.