Permit Case Summary

Case Number: Search Help

Case Number:SEP2003-00021 Case Status:Finaled Date Received:1/27/2003
Description:SEP93-533 NOW FILED HERE. Date Issued:2/24/2003
Applicant:RONALD MELHEIM Expiration Date:2/24/2006 12:00:00 AM
Site Address:190 MASONIC HALL RD Case Finaled:5/26/2004
Parcel No:901024007 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: OSS Inspection-1 Year
Date Completed: 10/1/2009
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 5/26/2004
Disposition: DONE
Description: OSS Inspection-6 Months
Date Completed: 5/25/2004
Disposition: DONE
Description: Issue permit (F)
Date Completed: 2/24/2003
Disposition: DONE
Description: App Substantially Complete-U
Date Completed: 1/28/2003
Disposition: DONE
Description: Case Entered
Date Completed: 1/28/2003
Disposition:
Description: Stormwater Review-U
Date Completed: 2/24/2003
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 2/24/2003
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 12/23/2002
Disposition: DONE
Description: Pressure test required
Date Completed: 2/19/2004
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 1/28/2003
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 1/28/2003
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: minimum land NOTICE TO TITLE
Wording This permit is granted based on the recorded RESTRICTIVE COVENANT combining parcel #'s 901-024-007 and 901-024-025 to meet the minimum land area required under WAC 246-272 Onsite Sewage Code. COVENANT recorded 1-24-03, #464928.

Title: food serv annual monitoring
Wording WAC 246-272 REQUIRES ANNUAL MONITORING OF THE ONSITE SEWAGE SYSTEM WHEN IT IS SERVING A FOOD SERVICE ESTABLISHMENT.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength wastewater only. Disposal of any other waste strength is considered a violation of this permit.

Title: BOD-WASTE STRENGTH MONITORING
Wording Waste Strength (BOD, TSS, Grease and oils) is to be monitored quarterly for the first year of operation and annually thereafter unless an expansion of services is proposed for which additional monitoring may be required. Responsibility is that of the owner. Results are to be submitted to the Jefferson County Health Dept.

Title: design flow/water usage monitorin
Wording Exceeding the permitted design flow of 1500 gal/day shall constitute a violation of this permit. Water usage monitoring shall be conducted weekly. These monitoring results shall be submitted to the Jefferson County Health Dept. no less than quarterly.

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet.

Title: AEROBIC TREATMENT SYS MANAGEMENT
Wording This onsite sewage system is permitted using an aerobic treatment unit (ATU) with UV disinfection. All ATU systems must have a continuous and perpetual management agreement in place for the life of the system. This management shall be provided by the Jefferson County PUD #1. A signed contract with PUD shall be required prior to final approval.

Title: ATU maintenance
Wording A maintenance and management contract is required with the manufacturers authorized representative. Maintenance of the system shall be completed by a manufacturers authorized representative at the frequency required by the manufacturer.

Title: ATU recording/ compliance
Wording The signed Notice for Maintenance and Monitoring of an Onsite Sewage System shall be recorded to the property title prior to final approval. Non-compliance with the contract or maintenance requirements is a violation of this permit.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED AT 6 MONTHS, AT ONE YEAR AND ANNUALLY THEREAFTER.

Title: protective barriers
Wording Permanent barriers are required along/around primary and reserve drainfield areas to protect from parking, driving, and other land disturbing activities prior to final.

Title: riser on d-box
Wording Distribution boxes shall be fitted with a riser to grade, constructed of durable materials and a secured lid, adequately sized to allow visible inspection of the liquid level in the box.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.


Case Findings
Below is a list of findings for this permit case. Findings typically record facts that the staff are using as the basis of their permit processing decisions.
Title: F-No ESAs Found
Wording The application was reviewed by Jefferson County staff for the presence of Environmentally Sensitive Areas (ESAs) and has concluded that the property DOES NOT contain Environmentally Sensitive Areas. Future proposals will be subject to a new ESA review and conditions may be added if ESAs are found on the property.