Permit Case Summary

Case Number: Search Help

Case Number:SEP2002-00287 Case Status:Finaled Date Received:12/6/2002
Description: Date Issued:12/20/2002
Applicant:BLAKE UNDERWOOD Expiration Date:12/20/2005 12:00:00 AM
Site Address:625 TOTEM RIDGE RD Case Finaled:7/23/2004
Parcel No:901114029 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: OSS Inspection-6 Months
Date Completed: 2/16/2005
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 7/23/2004
Disposition: DONE
Description: Issue permit (F)
Date Completed: 12/20/2002
Disposition: DONE
Description: App Substantially Complete-U
Date Completed: 12/9/2002
Disposition: DONE
Description: Case Entered
Date Completed: 12/9/2002
Disposition:
Description: Stormwater Review-U
Date Completed: 12/20/2002
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 12/20/2002
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 12/17/2002
Disposition: DONE
Description: Pressure test required
Date Completed: 7/1/2004
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 12/9/2002
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 12/9/2002
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: trench depth
Wording MAXIMUM TRENCH DEPTH 18 INCHES

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required.

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be sleeved/cased or equivalent.

Title: water tight tank
Wording Septic tank and pump chamber to be water tight. Extra protection (i.e. Bentonite) to be used around inlet, outlet, and risers due to high water table.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED AT 6 MONTHS, AT ONE YEAR AND .....EVERY 3 YEARS.

Title: surface water setback
Wording Setback to surface waters- 100' required from drainfield and reserve areas. 50' required from tanks.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: Setback - Drains
Wording A 30' setback shall be maintained from the disposal component and reserve area to any downslope footing, curtain or interceptor drain or drainage ditch.

Title: CUSTOM CONDITION-NO HOLD
Wording ALL OPEN SPACE AND WETLANDS AND THEIR BUFFERS SHALL BE MAINTAINED IN THEIR NATURALLY VEGETATED STATE.

Title: CUSTOM CONDITION-NO HOLD
Wording A GEOTECHNICAL REPORT MAY BE REQUIRED FOR BUILDING PERMIT

Title: CUSTOM CONDITION-NO HOLD
Wording CLEARING WITHIN GEOLOGICAL HAZARDOUS AREAS SHALL BE ALLOWED ONLY FROM APRIL 1 TO NOVEMBER 1

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.