Permit Case Summary

Case Number: Search Help

Case Number:SEP2002-00085 Case Status:Canceled Date Received:12/2/2002
Description:info from this case now filed with permit for expansion SEP03-94, and contains sep79-179. sp.12/13/02 this file also contains application as part of a preapplication conducted on 5/2/-02 Date Issued:12/16/2002
Applicant:CAROL FLETCHER Expiration Date:12/16/2005 12:00:00 AM
Site Address:173 CHIMACUM RD Case Finaled:
Parcel No:901024046 Other Cases Parcel Data Map It More Details

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: Cancel/withdraw application
Date Completed: 12/27/2005
Disposition: DONE
Description: Issue permit (F)
Date Completed: 12/16/2002
Disposition: DONE
Description: Pending letter; add inf (F)
Date Completed: 12/16/2002
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 12/2/2002
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 12/2/2002
Disposition: DONE
Description: Pending letter; add inf (F)
Date Completed: 12/13/2002
Disposition: DONE
Description: App Substantially Complete-U
Date Completed: 4/18/2002
Disposition: DONE
Description: Case Entered
Date Completed: 4/18/2002
Disposition:
Description: Initial Site Inspection by HD
Date Completed: 5/7/2002
Disposition: DONE
Description: EVALUATION OF EXISTING SYSTEM
Date Completed: 12/13/2002
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required.

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads.

Title: Tank Abandonment
Wording County records indicate one existing septic system SEP79-179 and from owner there is appearently another septic system that is not on record. All Existing tanks on parcel #901-024-046 shall be properly abandoned. They shall be pumped and filled with clean fill. Documentation to be provided to Health Dept. prior to final.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be sleeved/cased or equivalent.

Title: water tight tank
Wording Septic tank and pump chamber to be water tight. Extra protection (i.e. Bentonite) to be used around inlet, outlet, and risers due to high water table.

Title: SAND LINED TRENCH/BED
Wording TRENCH TO BE EXCAVATED TO 6" INTO THE TYPE 1 SOIL AND THEN BACKFILLED WITH ASTM 33 TYPE SAND TO 24" AND UP SIDE WALLS AS NEEDED PER DESIGN.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: minimum land NOTICE TO TITLE
Wording This permit is granted based on the recorded RESTRICTIVE COVENANT combining parcel # 901-024-005;046;and 048 to meet the minimum land area required under WAC 246-272 Onsite Sewage Code. COVENANT recorded...12/10/02............................

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength wastewater only. Disposal of any other waste strength is considered a violation of this permit.

Title: design flow/water usage monitorin
Wording Exceeding the permitted design flow of 1150 gal/day shall constitute a violation of this permit. Water usage monitoring shall be conducted.These monitoring results shall be submitted to the Jefferson County Health Dept. upon request.

Title: risers
Wording Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED EVERY AT 6 MONTHS, AT ONE YEAR AND EVERY 3 YEARS THEREAFTER.

Title: protective barriers
Wording Permanent barriers are required along/around primary and reserve drainfield areas to protect from parking, driving, and other land disturbing activities prior to final.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: Setback - Drains
Wording A 30' setback shall be maintained from the disposal component and reserve area to any downslope footing, curtain or interceptor drain or drainage ditch.

Title: ROAD CROSSING-NO HOLD
Wording This application includes a road crossing permit. Compliance with permit is required.

Title: CUSTOM CONDITION-NO HOLD
Wording Design flows for this system are proposed for two buildings: one building to be a 3 room motel with laudary, including 2 employees calculated at 584 gallons per day. The second building to be retail space with calculated flows of 538 gallons per day. Total flow calculated at 1150 gallons per day.