Permit Case Summary

Case Number: Search Help

Case Number:SEP2002-00011 Case Status:Finaled Date Received:1/14/2002
Description:lot 14, sep99-290 with this file. Tank and pump chamber connected to System C Date Issued:1/22/2002
Applicant: BRODERS INC Expiration Date:1/22/2005 12:00:00 AM
Site Address:274 PORT HADLOCK HEIGHTS RD Case Finaled:10/21/2002
Parcel No:989506114 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 10/21/2002
Disposition: DONE
Description: Issue permit (F)
Date Completed: 1/22/2002
Disposition: DONE
Description: App Substantially Complete-U
Date Completed: 1/14/2002
Disposition: DONE
Description: Case Entered
Date Completed: 1/14/2002
Disposition:
Description: Stormwater Review-U
Date Completed: 1/22/2002
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 1/22/2002
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 1/22/2002
Disposition: DONE
Description: Pressure test required
Date Completed:
Disposition:
Description: Print ESA Review Form-F
Date Completed: 1/14/2002
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 1/14/2002
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads.

Title: protection from vehicular traffic
Wording Septic tank and pump tank are to be completely protected from vehicular traffic or mechanical disturbance.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Septic tank and pump chamber to be water tight. Extra protection (i.e. Bentonite) to be used around inlet, outlet, and risers due to high water table.

Title: community df-tanks only
Wording Installer will verify with the system manager, the Jefferson County PUD #1, and the designer for specifications of pump requirements and inspections required by either party.

Title: comm- sep tank inspection
Wording Health Department is to be contacted for a final inspection of the septic tank and pump chamber prior to covering.

Title: comm- final approval
Wording Final approval of the sewage disposal permit will be given at the time our office has written notification by the PUD and/or the designer that inspections have been made and the installation meets their satisfaction.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: env. sensitive area conditions
Wording Compliance with the Environmentally Sensitive Areas Review conditions is required.

Title: risers
Wording Risers are required to grade with secured lids over the inlet and outlet of the septic tank. Minimum 24" riser over inlet.

Title: conventional-asbuilt required
Wording An asbuilt drawing and certification of completion by the installer is required prior to final approval.

Title: protective barriers
Wording Permanent barriers are required along/around primary and reserve drainfield areas to protect from parking, driving, and other land disturbing activities prior to final.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.