Permit Case Summary

Case Number: Search Help

Case Number:SEP2001-00173 Case Status:Finaled Date Received:9/18/2001
Description:Permit #SEP97-311 is filed with this permit. Date Issued:9/27/2001
Applicant:ARCHIE UNDERWOOD Expiration Date:9/27/2004 12:00:00 AM
Site Address:161 ANN KIVLEY DR Case Finaled:7/27/2004
Parcel No:972000025 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: OSS Inspection-1 Year
Date Completed: 2/18/2010
Disposition: DONE
Description: OSS Inspection-1 Year
Date Completed: 7/17/2007
Disposition: DONE
Description: OSS Inspection-6 Months
Date Completed: 7/12/2006
Disposition: DONE
Description: OSS Inspection-6 Months
Date Completed: 1/13/2006
Disposition: DONE
Description: OSS Inspection-6 Months
Date Completed: 7/14/2005
Disposition: DONE
Description: OSS Inspection-6 Months
Date Completed: 1/26/2005
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 7/27/2004
Disposition: DONE
Description: Issue permit (F)
Date Completed: 9/27/2001
Disposition: DONE
Description: Det. of Completeness-UF
Date Completed: 10/1/2001
Disposition:
Description: Issue permit (F)
Date Completed: 9/27/2001
Disposition: DONE
Description: Case Entered
Date Completed: 9/18/2001
Disposition:
Description: Stormwater Review-U
Date Completed: 9/27/2001
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 9/27/2001
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 9/26/2001
Disposition: DONE
Description: Pressure test required
Date Completed: 7/1/2004
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 9/18/2001
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 9/18/2001
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: other setbacks req.
Wording 10' min setback required from ditch upslope of glendon, and from any portion of drainfield to any water line.

Title: dry season installation
Wording Dry season installation required.

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Septic tank and pump chamber to be water tight. Extra protection (i.e. Bentonite) to be used around inlet, outlet, and risers due to high water table.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: risers
Wording Risers are required to grade with secured lids over the inlet and outlet of the septic tank. Minimum 24" riser over inlet.

Title: reduced size df
Wording Performance monitoring schedule for treatment systems followed by reduced sized drainfield/infiltrative area shall be :1) Two times per year (once every six months) during the first and second year following installation. 2) One time per year beginning with the third year following installation. 3) In response to complaints or problems.

Title: protective barriers
Wording Permanent barriers are required along/around primary and reserve drainfield areas to protect from parking, driving, and other land disturbing activities prior to final.

Title: CUSTOM CONDITION-NO HOLD
Wording Contact health department for inspection of exposed rim of the biofilter prior to covering. Provide 24 hours notice.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.