Permit Case Summary

Case Number: Search Help

Case Number:SEP2001-00103 Case Status:Finaled Date Received:7/6/2001
Description:TANK ONLY sep86-00123 filed with this permit Date Issued:8/8/2001
Applicant: LUTHERAN CHURCH OF REDEEMER Expiration Date:8/8/2004 12:00:00 AM
Site Address:47 REDEEMER WAY Case Finaled:9/11/2001
Parcel No:901114000 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: File Archived
Date Completed: 12/17/2002
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 9/11/2001
Disposition: DONE
Description: Issue permit (F)
Date Completed: 8/8/2001
Disposition: DONE
Description: Review Complete-U
Date Completed: 7/24/2001
Disposition: DONE
Description: Pending letter; add inf (F)
Date Completed: 7/20/2001
Disposition: DONE
Description: App Substantially Complete-U
Date Completed: 7/24/2001
Disposition: DONE
Description: Case Entered
Date Completed: 7/6/2001
Disposition:
Description: Stormwater Review-U
Date Completed: 7/24/2001
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 7/24/2001
Disposition: DONE
Description: Consistency Review-U
Date Completed: 7/24/2001
Disposition: DONE
Description: RAP Review Complete-U
Date Completed: 7/6/2001
Disposition: DONE
Description: Initial Site Inspection by HD
Date Completed: 7/20/2001
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 7/6/2001
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: other setbacks req.
Wording Tank must be 10' min. from water line and 5' min. from foundation and property line.

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank

Title: transport line double cased
Wording Any portion of sewer line under a driven way is to be double cased or equivalent.

Title: community df-tanks only
Wording Site conditions may require a lift pump to connect to the existing system. Installer will verify with the designer for specifications of pump requirements and inspections required by the health department.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength wastewater only. Disposal of any other waste strength is considered a violation of this permit.

Title: design flow/water usage monitorin
Wording Exceeding the permitted design flow of 1200 gal/day shall constitute a violation of this permit. Existing use by the church is approximately 350 gallons per day according to water use records. This application is for a 240 gallon per day residance for a care taker to be added to the existing system.

Title: risers
Wording Risers are required to grade with secured lids over the inlet and outlet of the septic tank. Minimum 24" riser over inlet.

Title: conventional system monitoring
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED EVERY 6 YEARS.

Title: conventional-asbuilt required