Permit Case Summary

Case Number: Search Help

Case Number:SEP2000-00276 Case Status:Finaled Date Received:12/15/2000
Description:per SUB04-34, a BLA, this septic system now serves the ADU under BLD003-308 main res. under SEP01-152 Date Issued:1/26/2001
Applicant:HARVEY WINDLE Expiration Date:1/26/2004 12:00:00 AM
Site Address:302 TOTEM RIDGE RD Case Finaled:10/9/2003
Parcel No:901114026 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 10/9/2003
Disposition: DONE
Description: Issue permit (F)
Date Completed: 1/26/2001
Disposition: DONE
Description: Pending letter; add inf (F)
Date Completed: 1/26/2001
Disposition: DONE
Description: Initial Site Inspection
Date Completed: 1/8/2001
Disposition:
Description: Case Entered
Date Completed: 12/18/2000
Disposition:
Description: Review Case
Date Completed: 1/26/2001
Disposition: DONE
Description: Critical Area Review
Date Completed: 1/23/2001
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 12/18/2000
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 12/15/2000
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: asbuilt required
Wording An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: other setbacks req.
Wording 100 ft. setback from standing water in the designated wetland area must be maintained.

Title: dry season installation
Wording Dry season installation required.

Title: trench depth
Wording MAXIMUM TRENCH DEPTH 24INCHES

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required.

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around drainfield.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area. System must be installed in area of soil logs #6 and #9 as shown on site plan and staked in the field by Bernt 1/8/01.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: final approval
Wording Final approval of the sewage disposal permit will be given at the time our office has recieved as-built forms from the designer and inspections from this office have been completed.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: critical area waiver cond.
Wording Compliance with the conditions of the signed Critical Area Waiver is required.

Title: risers
Wording Risers are required to grade with secured lids over the inlet and outlet of the septic tank. Minimum 24" riser over inlet. Install riser to grade over distibution box.

Title: MONITORIN-NO HOLD
Wording Compliance with monitoring frequency is required in accordance with Table 1 of Jefferson County Ordinance 08-0921-00, On-Site Sewage Code 8.15. This site must be inspected every 6 years or at the time of sale.