Permit Case Summary

Case Number: Search Help

Case Number:SEP2000-00204 Case Status:Finaled Date Received:8/21/2000
Description:case filed with SEP99-161 for drainfield and primary tanks Date Issued:4/17/2001
Applicant: JEFFERSON COUNTY Expiration Date:4/17/2004 12:00:00 AM
Site Address:101 H J CARROLL PARK RD Case Finaled:11/19/2001
Parcel No:901113007 Other Cases Parcel Data Map It More Details

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: OSS Inspection-1 Year
Date Completed: 4/5/2007
Disposition: DONE
Description: OSS Inspection-1 Year
Date Completed: 4/6/2006
Disposition: DONE
Description: OSS Inspection-1 Year
Date Completed: 4/29/2005
Disposition: DONE
Description: OSS Inspection-3 Year
Date Completed: 4/21/2004
Disposition: DONE
Description: OSS Inspection-Custom Schedule
Date Completed: 3/4/2003
Disposition: DONE
Description: OSS Inspection-6 Months
Date Completed: 6/6/2002
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 11/19/2001
Disposition: DONE
Description: Pressure test required
Date Completed: 10/30/2001
Disposition: DONE
Description: REDESIGN APPR-retain renewdate
Date Completed: 4/17/2001
Disposition: DONE
Description: Redesign Submitted no form
Date Completed: 2/27/2001
Disposition:
Description: Issue permit (F)
Date Completed: 9/13/2000
Disposition: DONE
Description: Case Entered
Date Completed: 8/25/2000
Disposition:
Description: Stormwater Review
Date Completed: 9/10/2000
Disposition: DONE
Description: Review Case
Date Completed: 9/10/2000
Disposition: DONE
Description: Critical Area Review
Date Completed: 9/10/2000
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 8/25/2000
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: alternative-asbuilt required
Wording An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: well setback requirement
Wording Setbacks to all individual wells- 50' required from tanks and effluent transport lines. Setbacks to all public wells- 100' required from all onsite sewage system components.

Title: other setbacks req.
Wording 10 ft. separation required between water lines and effluent transport lines. If the lines must cross it shall be done as follows: The lies shall be perpendicular, the effluent transport line shall be a minimum of 18" below the water line and double cased.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: risers
Wording Risers are required to grade with secured lids over the inlet and outlet of the septic tank. Minimum 24" riser over inlet.

Title: PUMP CHAMBER-NO HOLD
Wording Pump chamber shall have riser to grade, panel provided with alarm, manual on switch and dose counter. Floats shall be provided on a freestanding post attached to the riser for accessibility. There shall be an alarm and an on/off float at a minimum. A redundant off/low level float may be provided.