Permit Case Summary

Case Number: Search Help

Case Number:SEP2000-00174 Case Status:Finaled Date Received:7/19/2000
Description:WAS sep94-389 a failed system Date Issued:7/26/2000
Applicant:WENDY SANDBERG GARCIA Expiration Date:7/26/2002 12:00:00 AM
Site Address:2612 ANDERSON LAKE RD Case Finaled:5/16/2002
Parcel No:901104004 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: OSS Inspection-3 Year
Date Completed: 7/14/2005
Disposition: DONE
Description: OSS Inspection-1 Year
Date Completed: 7/30/2003
Disposition: DONE
Description: OSS Inspection-6 Months
Date Completed: 1/22/2003
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 5/16/2002
Disposition: DONE
Description: Renew Permit
Date Completed: 7/25/2001
Disposition: DONE
Description: Issue permit (F)
Date Completed: 7/26/2000
Disposition: DONE
Description: Case Entered
Date Completed: 7/21/2000
Disposition:
Description: Stormwater Review
Date Completed: 7/24/2000
Disposition: DONE
Description: Review Case
Date Completed: 7/26/2000
Disposition: DONE
Description: Critical Area Review
Date Completed: 7/26/2001
Disposition: DONE
Description: Pressure test required
Date Completed: 4/4/2002
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 7/21/2000
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test, 48 hour notice to be given.

Title: asbuilt required
Wording An asbuilt drawing and certification of completion by the designer is required prior to final approval.ASBUILT REPLACED 5/2/02 prb

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required.

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads, per design

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: SAND LINED TRENCH/BED
Wording TRENCH TO BE EXCAVATED TO 8O" OR 12 INCHES INTO SANDS BELOW AND THEN BACKFILLED WITH ASTM 33 TYPE SAND TO 8" AS PER DESIGN.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: risers