Permit Case Summary

Case Number: Search Help

Case Number:SEP2000-00172 Case Status:Finaled Date Received:7/19/2000
Description:this file contains SEP74-00270, SEP87-143 and SEP10-109 Date Issued:8/17/2000
Applicant:EARL WOODLEY Expiration Date:8/17/2003 12:00:00 AM
Site Address:211 CHIMACUM RD Case Finaled:12/7/2000
Parcel No:901024050 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: Close Case/Retrn status to "F"
Date Completed: 11/21/2014
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 12/7/2000
Disposition: DONE
Description: Issue permit (F)
Date Completed: 8/17/2000
Disposition: DONE
Description: Case Entered
Date Completed: 7/19/2000
Disposition:
Description: Stormwater Review
Date Completed: 7/20/2000
Disposition: DONE
Description: Review Case
Date Completed: 8/17/2000
Disposition: DONE
Description: Critical Area Review
Date Completed: 7/20/2000
Disposition: DONE
Description: Pressure test required
Date Completed: 11/20/2000
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 7/19/2000
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test, 48 hour notice to be given.

Title: asbuilt required
Wording An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: well setback requirement
Wording Setbacks to Public wells - 100' required to all onsite sewage system components. Setbacks to individual wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required.

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads.

Title: Tank Abandonment
Wording Existing tanks shall be properly abandoned. They shall be pumped and filled with clean fill. Documentation to be provided to Health Dept. prior to final.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: SAND LINED TRENCH/BED
Wording TRENCH TO BE EXCAVATED TO SPECIFIED DESIGN DEPTH AND THEN BACKFILLED WITH A MINIMUM OF 24" OF ASTM 33 TYPE SAND PRIOR TO PLACEMENT OF DRAINFIELD BED.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: minimum land NOTICE TO TITLE
Wording This permit is granted based on the recorded NOTICE TO TITLE combining lots Tax 73 and Tax 109 of STR 2-29N-1W to meet the minimum land area required under WAC 246-272 Onsite Sewage Code. NOTICE recorded 8-16-2000, #436326

Title: food serv annual monitoring
Wording WAC 246-272 REQUIRES ANNUAL MONITORING OF THE ONSITE SEWAGE SYSTEM WHEN IT IS SERVING A FOOD SERVICE ESTABLISHMENT.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength waste water only. Disposal of any other waste streams is considered a violation of this permit.

Title: BOD-WASTE STRENGTH MONITORING
Wording Waste Strength (CBOD, TSS, Grease and oils) is to be monitored quarterly for the first year of operation and annually thereafter. Responsibility is that of the owner. Results are to be submitted to the Jefferson County Health Dept.

Title: design flow/water usage monitorin
Wording Exceeding the permitted design flow of 450 gal/day shall constitute a violation of this permit. Water usage monitoring shall be conducted daily for the first two months & weekly thereafter. These monitoring results shall be submitted to the Jefferson County Health Dept. no less than quarterly.

Title: LICENSED INSTALLER-NO HOLD
Wording This commercial system shall be installed by an installer licensed to operate in Jefferson County.