Case Number:SEP2000-00161 Case Status:Finaled Date Received:6/29/2000
Description: Date Issued:8/12/2000
Applicant:ELIZABETH CORNETT Expiration Date:8/12/2003 12:00:00 AM
Site Address:181 RANDOLPH ST Case Finaled:9/10/2001
Parcel No:989400302 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: OSS Inspection-Custom Schedule
Date Completed: 4/24/2003
Disposition: DONE
Description: OSS Inspection-6 Months
Date Completed: 10/4/2002
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 9/10/2001
Disposition: DONE
Description: Issue permit (F)
Date Completed: 8/12/2000
Disposition: DONE
Description: Case Entered
Date Completed: 7/5/2000
Disposition:
Description: Stormwater Review
Date Completed: 7/12/2000
Disposition: DONE
Description: Review Case
Date Completed: 8/12/2000
Disposition: DONE
Description: Critical Area Review
Date Completed: 7/12/2000
Disposition: DONE
Description: Pressure test required
Date Completed: 6/28/2001
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 7/5/2000
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test, 48 hour notice to be given.

Title: asbuilt required
Wording An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around drainfield.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: SAND LINED TRENCH/BED
Wording TRENCH TO BE EXCAVATED TO 48" DEPTH AND THEN BACKFILLED WITH ASTM 33 TYPE SAND TO 24" AND UP SIDE WALLS AS PER DESIGN.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: minimum land NOTICE TO TITLE
Wording This permit is granted based on recording a NOTICE TO TITLE combining lots 2, 3, 4 of block 3, Port Hadlock to meet the minimum land area required under WAC 246-272 Onsite Sewage Code. NOTICE to be recorded prior to final.

Title: ADU/no builing permit assured
Wording Approval of this onsite sewage permit that includes an accessory dwelling unit does not assure that a building permit for an accessory dwelling unit will be approved. Building permit applications are subject to the requirements at the time of application, of the Jeff. Co. Building Code, Zoning Ordinance, Comprehensive Land Use Plan and Land Use Procedures Ordinance as well as any other environmental approvals duly adopted by Jefferson County, the State of Washington or any other agency with Jurisdiction.

Title: EXISTING RESIDENCE-NO HOLD
Wording Existing residence does not have a permitted onsite sewage system. Full evaluation required prior to issuance of any building permit if use of existing system is proposed.