Case Number: Search Help

Case Number:SEP2000-00083 Case Status:Finaled Date Received:5/2/2000
Description: Date Issued:5/30/2000
Applicant:EUGENE BRANDON Expiration Date:5/30/2003 12:00:00 AM
Site Address:164 1ST ST Case Finaled:1/21/2004
Parcel No:962900010 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: OSS Inspection-1 Year
Date Completed: 6/6/2007
Disposition: DONE
Description: OSS Inspection-1 Year
Date Completed: 6/23/2006
Disposition: DONE
Description: OSS Inspection-6 Months
Date Completed: 6/23/2005
Disposition: DONE
Description: OSS Inspection-6 Months
Date Completed: 12/8/2004
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 1/21/2004
Disposition: DONE
Description: REDESIGN APPR-retain renewdate
Date Completed: 5/15/2003
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 4/23/2003
Disposition: DONE
Description: Env. Sensitive Area Review-U
Date Completed: 5/15/2003
Disposition: DONE
Description: REDESIGN SUBMITTED (F)
Date Completed: 5/7/2003
Disposition: DONE
Description: Issue permit (F)
Date Completed: 5/30/2000
Disposition: DONE
Description: Case Entered
Date Completed: 5/2/2000
Disposition:
Description: Stormwater Review
Date Completed: 5/3/2000
Disposition: DONE
Description: Review Case
Date Completed: 5/30/2000
Disposition: DONE
Description: Critical Area Review
Date Completed: 5/3/2000
Disposition: DONE
Description: Pressure test required
Date Completed: 1/15/2004
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 5/2/2000
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 AND JEFFERSON COUNTY CODE 8.15 ALL SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM. While the County strongly recommends that the property owner allow inspectors to enter their property to inspect the system in order to insure that the system is functioning correctly, the property owner always has the right under the Fourth Amendment and our State Constitution, to refuse the inspectors access to their property. The property owner never loses the right to refuse access and can do so despite never having refused access before.

Title: pressure test observation
Wording Health Dept. required to observe pressure test, 48 hour notice to be given.

Title: asbuilt required
Wording An asbuilt drawing and certification of completion by the designer is required prior to final approval.

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: SAND LINED TRENCH/BED
Wording TRENCH TO BE EXCAVATED TO DESIGNED DEPTH AND THEN BACKFILLED WITH ASTM 33 TYPE SAND TO 24" AND UP SIDE WALLS AS PER DESIGN.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: risers
Wording Risers are required to grade with secured lids over the inlet and outlet of the septic tank. Minimum 24" riser over inlet.

Title: MONITORING SCHEDULE
Wording As per Jefferson County Code 8.15 all onsite sewage systems require monitoring. Monitoring shall be provided by an approved entity. THIS SYSTEM IS REQUIRED TO BE INSPECTED AT 6 MONTHS, AT ONE YEAR AND ANNUALLY THEREAFTER.

Title: System Capacity-no ADU
Wording This system as designed and approved is sized for only one single family residence. It is not sized for an Accessory Dwelling Unit (ADU). The minimum daily design flow per residence is 240 GPD.

Title: FILL-NO HOLD
Wording A maximum of 12" of fill to be placed over system. Excess fill on site is NOT to be placed on the drainfield or reserve areas.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.