Permit Case Summary

Case Number: Search Help

Case Number:SEP1999-00336 Case Status:Finaled Date Received:12/22/1999
Description:BLD00-40 Lot 18 TO COMMUNITY SYSTEM "B", SEP95-0291 Date Issued:1/11/2000
Applicant: BRODERS, INC Expiration Date:1/11/2003 12:00:00 AM
Site Address:334 PORT HADLOCK HEIGHTS RD Case Finaled:3/30/2000
Parcel No:989506118 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 3/30/2000
Disposition: DONE
Description: REDESIGN APPR-retain renewdate
Date Completed: 1/21/2000
Disposition: DONE
Description: Issue permit (F)
Date Completed: 1/11/2000
Disposition: DONE
Description: Case Entered
Date Completed: 12/23/1999
Disposition:
Description: Stormwater Review
Date Completed: 12/27/1999
Disposition: DONE
Description: Review Case
Date Completed: 1/11/2000
Disposition: DONE
Description: Critical Area Review
Date Completed: 12/27/1999
Disposition: DONE
Description: Septic Permit Application (F)
Date Completed: 12/23/1999
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pressure test observation
Wording Health Dept. required to observe pump test, 48 hour notice to be given.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and pump chamber.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: community df-tanks only
Wording Installer will verify with the system manager, and the designer for specifications of pump requirements and inspections required by either party.

Title: septic tank inspection
Wording Health Department is to be contacted for a final inspection of the septic tank and pump chamber prior to covering.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: risers
Wording Risers are required to grade with secured lids over the inlet and outlet of the septic tank. Minimum 24" riser over inlet. Riser required to grade on the pump chamber.