Permit Case Summary

Case Number: Search Help

Case Number:SEP1999-00180 Case Status:Finaled Date Received:6/15/1999
Description:SEP70-60 Valid for DF only Filed Here Date Issued:10/3/2003
Applicant:MICHAEL HAMILTON Expiration Date:10/8/2002 12:00:00 AM
Site Address:124 N WATER ST Case Finaled:7/25/2018
Parcel No:966200008 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 7/25/2018
Disposition: DONE
Description: Monitoring Agreemt Sent (Fm)
Date Completed: 7/24/2018
Disposition: DONE
Description: Mon Agreement ATU Attach (Fm)
Date Completed: 7/24/2018
Disposition: DONE
Description: AsBuilt from engineer req
Date Completed: 3/28/2005
Disposition: DONE
Description: VIOLATION/COMPLIANCE Letter
Date Completed: 7/25/2018
Disposition: DONE
Description: OSS Inspection-1 Year
Date Completed: 2/13/2006
Disposition: DONE
Description: Incomplete Installation "I"
Date Completed: 7/25/2018
Disposition: DONE
Description: Incomplete Installation "I"
Date Completed: 8/19/2003
Disposition: DONE
Description: OSS Inspection-6 Months
Date Completed: 2/6/2003
Disposition: DONE
Description: OSS Inspection-1 Year
Date Completed: 10/2/2003
Disposition: DONE
Description: Redesign APPR & ISSUED-newdate
Date Completed: 8/7/2002
Disposition: DONE
Description: Print ESA Review Form-F
Date Completed: 7/17/2002
Disposition: DONE
Description: REDESIGN SUBMITTED (F)
Date Completed: 8/7/2002
Disposition: DONE
Description: Renew Permit
Date Completed: 7/27/2001
Disposition: DONE
Description: Renewal Notice Printed (F)
Date Completed: 7/10/2001
Disposition: DONE
Description: Renew Permit
Date Completed: 7/21/2000
Disposition: DONE
Description: Renewal Notice Printed (F)
Date Completed: 7/10/2000
Disposition: DONE
Description: Issue permit (F)
Date Completed: 7/27/1999
Disposition: ISS
Description: Case Entered
Date Completed: 6/15/1999
Disposition:
Description: Stormwater Review
Date Completed: 6/29/1999
Disposition:
Description: Review Case
Date Completed: 7/27/1999
Disposition: ISS
Description: Critical Area Review
Date Completed: 6/29/1999
Disposition:
Description: Pressure test required
Date Completed: 5/14/2002
Disposition: DONE
Description: REDESIGN SUBMITTED (F)
Date Completed: 6/18/1999
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test when system fully installed/complete, 48 hours notice to be provided for scheduling.

Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: other setbacks req.
Wording 50 ft. setback from surface water to be maintained from tanks and sandfilter basin.

Title: reserve area, alternative
Wording When/if designated reserve area is utilized an alternative system providing an additional level of treatment may be required.

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around drainfield.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: nonconforming repair
Wording This system does not conform to current code. It is a Table VI repair and is required to meet treatment standard 1. It does not meet the standards of WAC 246-272 in the following manner: The disposal component is less than 50' from surface water and has less than 12" of vertical separation. A copy of this permit is recorded with the Jefferson County Auditor.

Title: marine expansion
Wording Marine expansions as defined by WAC 246-272-010 (12) are prohibited under a Table VI repair.

Title: treatment standard
Wording This system meets Treatment Standard I as per State Guidelines and requires annual monitoring.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: UDC compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site.

Title: critical area waiver cond.
Wording Compliance with the conditions of the signed Critical Area Waiver is required.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength waste water only. Disposal of any other waste streams is considered a violation of this permit.

Title: AEROBIC TREATMENT SYS MANAGEMENT
Wording This onsite sewage system is permitted using an aerobic treatment unit (ATU) with UV disinfection. All ATU systems must have a continuous and perpetual management agreement in place for the life of the system. This management shall be provided by the Jefferson County PUD #1. A signed contract with PUD shall be required prior to final approval.

Title: ATU maintenance
Wording Maintenance of the system shall be completed by a manufacturers authorized representative at the frequency required by the manufacturer. That frequency may be increased to meet State requirements for Treatment Standard 1 systems.

Title: ATU contract recordng/ compliance
Wording The signed maintenance contract with the manufacturer's authorized representative shall be recorded to the property title prior to final approval. Non-compliance with the contract or maintenance requirements is a violation of this permit.

Title: Water line setback
Wording 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components.

Title: VIOLATION-limited permit life
Wording This permit was issued to correct a violation of WAC 246-272. The permit must be completed within 90 days of the date of issuance.

Title: Stormwater BMPs
Wording The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems.