Permit Case Summary

Case Number: Search Help

Case Number:SEP1998-00243 Case Status:Finaled Date Received:11/19/1998
Description:Tri Area Community Center Date Issued:3/1/2002
Applicant: JEFFERSON COUNTY Expiration Date:3/8/1999 12:00:00 AM
Site Address:10 WEST VALLEY RD Case Finaled:3/10/2016
Parcel No:901113015 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 3/10/2016
Disposition: DONE
Description: Pressure test required
Date Completed: 10/2/2015
Disposition: DONE
Description: INSTALLATION START NOTICE
Date Completed: 10/2/2015
Disposition: DONE
Description: Monitoring Agreemt Sent (Fm)
Date Completed: 6/15/2015
Disposition: DONE
Description: AsBuilt from engineer req
Date Completed: 9/29/2015
Disposition: DONE
Description: Incomplete Installation "I"
Date Completed: 3/1/2002
Disposition: DONE
Description: Renewal Notice Printed (F)
Date Completed: 12/4/2000
Disposition: DONE
Description: PUD Monitoring Contract ltr"L"
Date Completed: 12/4/2000
Disposition: DONE
Description: Issue permit (F)
Date Completed: 12/8/1998
Disposition: ISS
Description: Case Entered
Date Completed: 11/19/1998
Disposition:
Description: Stormwater Review
Date Completed: 11/25/1998
Disposition:
Description: Review Case
Date Completed: 12/8/1998
Disposition: ISS
Description: Critical Area Review
Date Completed: 11/25/1998
Disposition:
Description: Septic Permit Application (F)
Date Completed: 11/23/1998
Disposition:
Description: Pressure test required
Date Completed: 4/13/2000
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test, 48 hour notice to be given.

Title: well setback requirement
Wording Setbacks to individual wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines. Setbacks to public wells - 100' required from all onsite sewage system components.

Title: other setbacks req.
Wording 10 ft. separation required between water lines and any portion of wastewater system.

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around drainfield.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: SAND LINED TRENCH/BED
Wording TRENCH TO BE EXCAVATED TO 36" - 48" DEPTH AND THEN BACKFILLED WITH ASTM 33 TYPE SAND TO 24" AS PER DESIGN.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength waste water only. Disposal of any other waste streams is considered a violation of this permit.

Title: BOD-WASTE STRENGTH MONITORING
Wording Waste Strength (BOD, TSS, Grease and oils) is to be monitored quarterly for the first year of operation and annually thereafter. Responsibility is that of the owner. Results are to be submitted to the Jefferson County Health Dept.

Title: design flow/water usage monitorin
Wording Exceeding the permitted design flow of 1500 gal/day shall constitute a violation of this permit. Water usage monitoring shall be conducted daily if/when requested by the Health Dept. These monitoring results shall be submitted to the Jefferson County Health Dept. upon request.

Title: food serv annual monitoring
Wording WAC 246-272 REQUIRES ANNUAL MONITORING OF THE ONSITE SEWAGE SYSTEM WHEN IT IS SERVING A FOOD SERVICE ESTABLISHMENT.

Title: minimum land NOTICE TO TITLE
Wording This permit is granted based on the recorded NOTICE TO TITLE combining lots 2-8 of block 2, of Irondale Orchard Tracts and Tax 5 & 6 of STR 11/29/1W to meet the minimum land area required under Administrative Rule for compliance with the Interim Critical Areas Ordinance No. 14-0626-95 and WAC 246-272. NOTICE recorded Dec. 3, 1998.Vol 628 Pg 696-697.

Title: risers
Wording Risers are required to grade with secured lids over all compartments of the tanks.