Description:
|
| | |
Decommission SEP sys "C"
|
|
Date Completed:
|
| | |
12/30/2005
|
|
Disposition:
|
| | |
DONE
|
|
|
Description:
|
| | |
SEPTIC PERMIT FINALED "F"
|
|
Date Completed:
|
| | |
2/23/1999
|
|
Disposition:
|
| | |
DONE
|
|
|
Description:
|
| | |
Issue permit (F)
|
|
Date Completed:
|
| | |
10/30/1998
|
|
Disposition:
|
| | |
ISSU
|
|
|
Description:
|
| | |
Case Entered
|
|
Date Completed:
|
| | |
10/8/1998
|
|
Disposition:
|
| | |
|
|
|
Description:
|
| | |
Stormwater Review
|
|
Date Completed:
|
| | |
10/14/1998
|
|
Disposition:
|
| | |
|
|
|
Description:
|
| | |
Review Case
|
|
Date Completed:
|
| | |
10/30/1998
|
|
Disposition:
|
| | |
ISSU
|
|
|
Description:
|
| | |
Critical Area Review
|
|
Date Completed:
|
| | |
10/26/1998
|
|
Disposition:
|
| | |
|
|
|
Description:
|
| | |
Septic Permit Application (F)
|
|
Date Completed:
|
| | |
10/8/1998
|
|
Disposition:
|
| | |
|
|
|
Title:
|
| | |
well setback requirement
|
|
Wording
|
| | |
100 foot setback to public drinking water wells and 50 foot setbacks to all non public wells must be maintained from the vault.
|
|
|
Title:
|
| | |
other setbacks req.
|
|
Wording
|
| | |
50 ft. minimum setback from surface waters to be maintained.
|
|
|
Title:
|
| | |
divert drainage
|
|
Wording
|
| | |
Divert all sources of drainage away from tank area.
|
|
|
Title:
|
| | |
water tight tank
|
|
Wording
|
| | |
1000 gallon asphaultic emulsion or equivalent vault tank required
|
|
|
Title:
|
| | |
septic tank inspection
|
|
Wording
|
| | |
Health Department is to be contacted for a final inspection of the vault prior to covering.
|
|
|
Title:
|
| | |
no building permit guarantee
|
|
Wording
|
| | |
Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.
|
|
|
Title:
|
| | |
critical area compliance
|
|
Wording
|
| | |
Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.
|
|
|
Title:
|
| | |
holding tank
|
|
Wording
|
| | |
Risers to grade with secured lids shall be located over all compartments. Access ports intended for use as pump-out sites shall be fitted with an impervious pad that slopes towards the access. All pumping and related service must be performed by a Jefferson County licensed septic system pumper. Prior to final approval, the applicant shall submit to the Health Dept. written documentation of a service contract with a licensed pumper. Permit Holder shall maintain and keep operaitonal records which include pumping intervals, sewage volume, disposal site, service and repair records. These records shall be available upon request of the Health officer representative.
|
|