Permit Case Summary

Case Number: Search Help

Case Number:SEP1998-00211 Case Status: Date Received:10/8/1998
Description:This vault toilet is to be removed in favor of SEP05-106. All filed there. CANCELLED SEP94-42 NOW FILED HERE Date Issued:10/30/1998
Applicant: WA ST PARKS & RECREATION Expiration Date:10/30/1999 12:00:00 AM
Site Address: HWY 101 Case Finaled:2/23/1999
Parcel No:502313013 Other Cases Parcel Data Map It More Details

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: Decommission SEP sys "C"
Date Completed: 12/30/2005
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 2/23/1999
Disposition: DONE
Description: Issue permit (F)
Date Completed: 10/30/1998
Disposition: ISSU
Description: Case Entered
Date Completed: 10/8/1998
Disposition:
Description: Stormwater Review
Date Completed: 10/14/1998
Disposition:
Description: Review Case
Date Completed: 10/30/1998
Disposition: ISSU
Description: Critical Area Review
Date Completed: 10/26/1998
Disposition:
Description: Septic Permit Application (F)
Date Completed: 10/8/1998
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: well setback requirement
Wording 100 foot setback to public drinking water wells and 50 foot setbacks to all non public wells must be maintained from the vault.

Title: other setbacks req.
Wording 50 ft. minimum setback from surface waters to be maintained.

Title: divert drainage
Wording Divert all sources of drainage away from tank area.

Title: water tight tank
Wording 1000 gallon asphaultic emulsion or equivalent vault tank required

Title: septic tank inspection
Wording Health Department is to be contacted for a final inspection of the vault prior to covering.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: holding tank
Wording Risers to grade with secured lids shall be located over all compartments. Access ports intended for use as pump-out sites shall be fitted with an impervious pad that slopes towards the access. All pumping and related service must be performed by a Jefferson County licensed septic system pumper. Prior to final approval, the applicant shall submit to the Health Dept. written documentation of a service contract with a licensed pumper. Permit Holder shall maintain and keep operaitonal records which include pumping intervals, sewage volume, disposal site, service and repair records. These records shall be available upon request of the Health officer representative.