Permit Case Summary

Case Number: Search Help

Case Number:SEP1998-00139 Case Status:Finaled Date Received:6/18/1998
Description:serves Chimacum Creek Primary school Date Issued:3/1/2002
Applicant: CHIMACUM SCHOOL DIST 49 Expiration Date:3/22/2001 12:00:00 AM
Site Address:313 NESS' CORNER RD Case Finaled:12/31/2008
Parcel No:901023010 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 12/31/2008
Disposition: DONE
Description: Incomplete Installation "I"
Date Completed: 3/1/2002
Disposition: DONE
Description: Renew Permit
Date Completed: 3/21/2000
Disposition: DONE
Description: Renewal Notice Printed (F)
Date Completed: 3/6/2000
Disposition: DONE
Description: Issue permit (F)
Date Completed: 3/22/1999
Disposition: ISS
Description: Pending letter; add inf (F)
Date Completed: 3/22/1999
Disposition: P
Description: Case Entered
Date Completed: 6/18/1998
Disposition:
Description: Stormwater Review
Date Completed: 3/22/1999
Disposition:
Description: Review Case
Date Completed: 3/22/1999
Disposition: ISS
Description: Critical Area Review
Date Completed: 3/22/1999
Disposition:
Description: Septic Permit Application (F)
Date Completed: 6/22/1998
Disposition:
Description: PUD contract required
Date Completed: 9/22/2004
Disposition: DONE
Description: AsBuilt from engineer req
Date Completed: 6/27/2008
Disposition: DONE
Description: Pressure test required
Date Completed: 8/23/2000
Disposition: DONE

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test, 48 hour notice to be given.

Title: well setback requirement
Wording Setbacks to all wells- 100' required from drainfield and reserve areas. 50' required from tanks and effluent transport lines.

Title: other setbacks req.
Wording 100 ft. setback from all surface waters to be maintained.

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets and 2.5 gpm shower heads.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around drainfield.

Title: installed on natural contours
Wording Drainlines are to be installed along the natural contours.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage, including roof drains away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: critical area waiver cond.
Wording Compliance with the conditions of the signed Critical Area Waiver is required.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength waste water only. Disposal of any other waste streams is considered a violation of this permit.

Title: BOD-WASTE STRENGTH MONITORING
Wording Waste Strength (BOD, TSS, Grease and oils) is to be monitored quarterly for the first year during operation (Oct., Feb. & May)and annually thereafter in May. Responsibility is that of the owner. Results are to be submitted to the Jefferson County Health Dept.

Title: design flow/water usage monitorin
Wording Exceeding the permitted design flow of 2000 gal/day shall constitute a violation of this permit. Water usage monitoring shall be conducted daily for the first two months of the school year & weekly thereafter. These monitoring results shall be submitted to the Jefferson County Health Dept. no less than quarterly.

Title: food serv annual monitoring
Wording WAC 246-272 REQUIRES ANNUAL MONITORING OF THE ONSITE SEWAGE SYSTEM WHEN IT IS SERVING A FOOD SERVICE ESTABLISHMENT.