Permit Case Summary

Case Number: Search Help

Case Number:SEP1997-00303 Case Status:Finaled Date Received:12/15/1997
Description: Date Issued:2/5/1998
Applicant:LAWRENCE SOLOMONSON Expiration Date:2/5/1999 12:00:00 AM
Site Address: KENNEDY RD Case Finaled:1/19/1999
Parcel No:942901403 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: OSS Inspection-5 Year
Date Completed: 11/7/2003
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 1/19/1999
Disposition:
Description: Issue permit (F)
Date Completed: 2/5/1998
Disposition: ISSU
Description: Pending letter; add inf (F)
Date Completed: 1/30/1998
Disposition: DOKE
Description: Case Entered
Date Completed: 12/15/1997
Disposition:
Description: Stormwater Review
Date Completed: 12/18/1997
Disposition:
Description: Review Case
Date Completed: 1/12/1998
Disposition: ISSU
Description: Critical Area Review
Date Completed: 1/30/1998
Disposition: OKAY
Description: Septic Permit Application (F)
Date Completed: 12/16/1997
Disposition:
Description: PUD contract required
Date Completed: 11/13/1998
Disposition:
Description: AsBuilt from engineer req
Date Completed: 1/19/1999
Disposition:
Description: Pressure test required
Date Completed: 10/5/1998
Disposition:
Description: Easement required
Date Completed: 1/16/1998
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: pressure test observation
Wording Health Dept. required to observe pressure test, 48 hour notice to be given.

Title: other setbacks req.
Wording 50 ft. setback from pond to septic & pump tanks as well as any septic transport line must be maintained.

Title: easement
Wording Recorded easement required for primary and/or reserve drainfields. Easement must be recorded with the Jefferson County Auditors office prior to receiving a final on this permit.

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around drainfield.

Title: staking of drainfield
Wording Contact designer prior to installation for staking of drainfield area.

Title: dose counter
Wording Dose counters are required in the control panel for all drainfield components.

Title: divert drainage
Wording Divert all sources of drainage away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: SAND LINED TRENCH/BED
Wording TRENCH TO BE EXCAVATED TO 36" DEPTH AND THEN BACKFILLED WITH 24" of ASTM 33 TYPE SAND AND UP SIDE WALLS AS PER DESIGN.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: domestic strength waste
Wording This onsite sewage system is designed for domestic strength waste water only. Disposal of any other waste streams is considered a violation of this permit.

Title: risers
Wording Risers are required to grade with secured lids over the inlet and outlet of the septic tank. Minimum 24" riser over inlet.