Case Number:SEP1997-00206 Case Status:Finaled Date Received:8/13/1997
Description: Date Issued:9/12/1997
Applicant: CITY OF PORT TOWNSEND Expiration Date:9/12/1998 12:00:00 AM
Site Address:21 KENNEDY RD Case Finaled:12/2/1997
Parcel No:959100101 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 12/2/1997
Disposition:
Description: Issue permit (F)
Date Completed: 9/12/1997
Disposition: ISS
Description: Case Entered
Date Completed: 8/13/1997
Disposition:
Description: Stormwater Review
Date Completed: 8/18/1997
Disposition:
Description: Review Case
Date Completed: 9/12/1997
Disposition: ISS
Description: Critical Area Review
Date Completed: 8/18/1997
Disposition:
Description: Septic Permit Application (F)
Date Completed: 8/14/1997
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: well setback requirement
Wording 100 ft. setback to all public water wells to be maintained

Title: other setbacks req.
Wording 50 ft. setback from all monitoring or individual wells to be maintained.

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance.

Title: transport line double cased
Wording Any portion of transport line within 100' of a public well is to be double cased as per DOE Criteria for Sewage Works.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: holding tank
Wording Risers to grade with secured lids shall be located over all compartments. Access ports intended for use as pump-out sites shall be fitted with an impervious pad that slopes towards the access. All pumping and related service must be performed by a Jefferson County licensed septic system pumper or the City and disposed of in an approved facility. Permit Holder shall maintain and keep operational records which include pumping intervals, sewage volume, disposal site, service and repair records. These records shall be available upon request of the Health officer representative. A high water float with an audio visual alarm shall be provided. The alarm shall be located within view of the holding tank in a watertight enclosure and approved by the State Electrical Inspector.