Permit Case Summary

Case Number: Search Help

Case Number:SEP1997-00147 Case Status:Finaled Date Received:6/12/1997
Description:Adding a Grease trap and septic tank only on 2nd building attached to SEP96-188 that is now filed here. Date Issued:7/10/1997
Applicant:JOHN GUNNING Expiration Date:7/10/1998 12:00:00 AM
Site Address:10632 RHODY DR Case Finaled:12/23/1997
Parcel No:942903605 Other Cases Parcel Data Map It More Details Parcels Images

Case Actions
Below is a list of actions that have been taken by staff for this permit case. They are sorted based on the date they were added to the database with most recent actions at the top. A value in the "Date Completed" field indicates that the action has been completed.
Description: OSS Inspection-2 Year
Date Completed: 7/11/2002
Disposition: DONE
Description: OSS Inspection-1 Year
Date Completed: 7/29/2004
Disposition: DONE
Description: SEPTIC PERMIT FINALED "F"
Date Completed: 12/23/1997
Disposition:
Description: Issue permit (F)
Date Completed: 7/10/1997
Disposition: ISS
Description: Case Entered
Date Completed: 6/12/1997
Disposition:
Description: Review Case
Date Completed: 7/9/1997
Disposition: ISS
Description: Critical Area Review
Date Completed: 6/16/1997
Disposition:
Description: Septic Permit Application (F)
Date Completed: 6/13/1997
Disposition:

Case Conditions
Below is a list of conditions for this permit case. Conditions typically record requirements that the applicant must meet to be in compliance with the permit.
Title: pud monitoring
Wording AS PER WAC 246-272 ALL ALTERNATIVE SYSTEMS REQUIRE MONITORING. THIS MONITORING IS PROVIDED BY AGREEMENT BETWEEN THE JEFFERSON COUNTY ENVIRONMENTAL HEALTH DIVISION AND THE JEFFERSON COUNTY PUBLIC UTILITY DISTRICT #1. THIS SEWAGE DISPOSAL SYSTEM WILL REQUIRE AN ACTIVE MONITORING CONTRACT WITH THE PUD #1 PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL SYSTEM.

Title: other setbacks req.
Wording 10 ft. setback from all waterlines to be maintained.

Title: easement
Wording Recorded easement required for primary and/or reserve drainfields prior to final approval. Easement to be recorded with the Jefferson County Auditors office.

Title: low use water fixures
Wording Low use water fixtures required, 1.6 gal. flush toilets

Title: protection from vehicular traffic
Wording All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Protective barriers are required around drainfield.

Title: divert drainage
Wording Divert all sources of drainage away from septic tank and drainfield area.

Title: transport line double cased
Wording Any portion of transport line under a driven way is to be double cased or equivalent.

Title: water tight tank
Wording Asphaultic emulsion or equivalent required on septic tank and/or pump chamber.

Title: no building permit guarantee
Wording Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required.

Title: critical area compliance
Wording Approval of this sewage disposal permit does not preclude the permit holder from complying with the Critical Areas Ordinance for other development on the site.

Title: BOD-WASTE STRENGTH MONITORING
Wording Waste Strength (BOD, TSS, Grease and oils) is to be monitored quarterly for the first year of operation and annually thereafter. Responsibility is that of the system owner. Results are to be submitted to the Jefferson County Health Dept.

Title: design flow/water usage monitorin
Wording Exceeding the permitted design flow shall constitute a violation of this permit. Water usage monitoring shall be conducted daily for the first two months & weekly thereafter. These monitoring results shall be submitted to the Jefferson County Health Dept. no less than quarterly.

Title: food serv annual monitoring
Wording WAC 246-272 REQUIRES ANNUAL MONITORING OF THE ONSITE SEWAGE SYSTEM WHEN IT IS SERVING A FOOD SERVICE ESTABLISHMENT.

Title: risers
Wording Risers are required to grade with secured lids over the inlet and outlet of the septic tank. Minimum 24" riser over inlet.